Common Firmware Error Codes

Attention:
Follow the procedure defined in "Checkpoints and Error Codes Index" on page 245. If you
replace FRUs or perform an action on an I/O subsystem and the problem is still not corrected, go to "MAP
1542: I/O Problem Isolation" on page 144 unless you were already directed to any MAP 154x by the error
code. Otherwise call support if the action(s) for an error code do not resolve the problem.
Attention:
If the error code that brought you to this chapter originated in the operating system error log,
please be aware that an error may require an additional 15 minutes to be propagated to the operating
system error log.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in the Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Error Code Description
B006 1403 Missing service processor resource
B006 1404 Service processor firmware fault
B006 1405 Service processor firmware fault
B006 1406 Service processor program error
B006 1407 Service processor resource allocation problem
B006 1408 Service processor program error
B006 1409 Service processor program error
B10F 1000 Service processor failure
B10F 1002 Service processor failure
B10F 1005 Service processor failure
B10F 1007 Service processor failure
B10F 1008 Service processor failure
B10F 100E Service processor boot flash corrupted
444
EserverpSeries 650 Service Guide
Action/
Possible Failing FRU
1. Check for system firmware updates.
2. Service processor/PCI backplane
Location: U0.1-P2
1. Check for system firmware updates.
2. Service processor/PCI backplane
Location: U0.1-P2
1. Check for system firmware updates.
2. Service processor/PCI backplane
Location: U0.1-P2
1. Check for system firmware updates.
2. Check for operating system updates
3. Service processor/PCI backplane
Location: U0.1-P2
1. Check for system firmware updates.
2. Check for operating system updates
3. Service processor/PCI backplane
Location: U0.1-P2
1. Check for system firmware updates.
2. Check for operating system updates
3. Service processor/PCI backplane
Location: U0.1-P2
1. Check for system firmware updates.
2. Service processor/PCI backplane
Location: U0.1-P2
Service processor/PCI backplane
Location: U0.1-P2
Service processor/PCI backplane
Location: U0.1-P2
Service processor/PCI backplane
Location: U0.1-P2
Service processor/PCI backplane
Location: U0.1-P2
Service processor/PCI backplane
Location: U0.1-P2
Service processor/PCI backplane
Location: U0.1-P2