Troubleshooting; Error Codes And Description - Daikin FTXG20LV1BW Service Manual

Inverter pair wall mounted type l-series
Hide thumbs Also See for FTXG20LV1BW:
Table of Contents

Advertisement

SiBE041401E

4. Troubleshooting

4.1

Error Codes and Description

System
Indoor
Unit
Outdoor
Unit
Service Diagnosis
Error Codes
00
Normal
U0★
Refrigerant shortage
U2
Low-voltage detection or over-voltage detection
U4
Signal transmission error (between indoor unit and outdoor unit)
UA
Unspecified voltage (between indoor unit and outdoor unit)
A1
Indoor unit PCB abnormality
A5
Freeze-up protection control / heating peak-cut control
A6
Fan motor (DC motor) or related abnormality
C4
Indoor heat exchanger thermistor or related abnormality
C7
Front panel open / close fault
C9
Room temperature thermistor or related abnormality
E1
Outdoor unit PCB abnormality
E5★
OL activation (compressor overload)
E6★
Compressor lock
E7★
DC fan lock
E8
Input overcurrent detection
EA
Four way valve abnormality
F3
Discharge pipe temperature control
F6
High pressure control in cooling
H0
Compressor system sensor abnormality
H6
Position sensor abnormality
H8
DC voltage / current sensor abnormality (20/25/35 class only)
H9
Outdoor temperature thermistor or related abnormality
J3★
Discharge pipe thermistor or related abnormality
J6
Outdoor heat exchanger thermistor or related abnormality
L3
Electrical box temperature rise
L4
Radiation fin temperature rise
L5★
Output overcurrent detection
P4
Radiation fin thermistor or related abnormality
: Displayed only when system-down occurs.
Description

Troubleshooting

Reference
Page
65
67
69
71
59
60
61
63
64
63
72
73
75
76
77
78
80
81
82
83
85
86
86
86
88
89
91
86
58