Download Print this page

Daikin RKN25KEVM Removal Procedure page 7

Advertisement

Si001170
Step
3
Peel the sealing
material and remove
the 2 upper screws.
4
Remove the 2 lower
screws.
5
Remove the fan motor
fixing frame.
Removal Procedure
Procedure
Sealing
material
Fan motor fixing frame
Removal of Outdoor Fan / Fan Motor
Points
(R14860)
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
(R14861)
Lead wire
(R14862)
Outdoor fan
(R3249)