Delete Programmed Devices; System Reset; Technical Specifications - Gemini 823 Installation And Use Manual

Table of Contents

Advertisement

14.0 - DELETE PROGRAMMED DEVICES

To carry out the operation successfully, make sure the required electrical connections
!
(door/bonnet switches and ignition) are properly connected.
To clear the alarm memory proceed as follows :
!
With the system disarmed, open the driver door and the bonnet and leave them open
The "
ON-OFF
" cycles must be carried out within 4 seconds otherwise the procedure is
!
!
Cycle ignition key 4 times within 4 sec. ("
with the key in the "
ON
" position.
!
A Beep, a Bop and a flash of the turn indicators will confirm the system is in delete mode. The status
LED will also power ON
.
!
Close the bonnet and k
eep it closed for at least 8 sec. to fully clear the memory.
!
If the bonnet is opened before 8 seconds, devices will not be deleted.
!
The status LED will power OFF to confirm the memory has been cleared
!
Turn ignition key OFF
.
!
A long Bop will confirm the end of the procedure.
PAGE 14 - INSTALLER MANUAL
invalidated.
ON-OFF ON-OFF ON-OFF ON
"-"
"-"
"-"
") ending the cycle
.
!
To reset the system proceed as follows:
.
!
Disconnect the alarm power supply
!
S
hort-circuit the RED and BLACK wires of the 2-pin
!
Power the
system
!
Remove the previously created short-circuit; the status LED will light up steady.
!
Turn ignition key ON;
!
Turn ignition key OFF;
!
No acoustic signals will confirm the end of the procedure
Current absorption @ 12Vdc with system armed and LED flashing

15.0 - SYSTEM RESET

A system reset will return the device to the factory default settings.
This procedure must therefore only be used in case of need.
.
LED
connector
; 4 Beeps and 4 flashes of the turn indicators will confirm the operation
reset is confirmed by a Beep and the siren will sound for approx. 3 seconds
the LED will power OFF.
.

16.0 - TECHNICAL SPECIFICATIONS

Power supply 823 - 822
Working temperature range
Turn indicators relay contact capacity
Engine immobilizer relay contact capacity
Alarm cycle duration
Siren output current capacity
.
.
.
12 Vdc
15mA
-30°C to +70°C
8A @ 20°C
8A @ 20°C
30 sec.
1A