Craftsman 137.218250 Owner's Manual page 5

2.7 hp (maximum developed) 10" inch blade 5000 r.p.m. table saw
Hide thumbs Also See for 137.218250:
Table of Contents

Advertisement

GROUNDING INSTRUCTIONS
IN THE EVENT OF A MALFUNCTION OR BREAKDOWN,
grounding provides a path of least resistance for electric
current and reduces the risk of electric shock. This tool
is equipped with an electric cord that has an equipment
grounding conductor and a grounding plug. The plug
MUST be plugged into a matching receptacle that is
properly installed and grounded in accordance with ALL
local codes and ordinances.
DO NOT MODIFY THE PLUG PROVIDED.
fit the receptacle, have the proper receptacle installed
by a qualified electrician.
IMPROPER CONNECTION
conductor can result in risk of electric shock. The
conductor with the green insulation (with or without
yellow stripes) is the equipment grounding conductor. If
repair or replacement of the electric cord or plug is
necessary, DO NOT connect the equipment grounding
conductor to a live terminal.
CHECK with a qualified electrician or service person if
you do not completely understand the grounding
instructions, or if you are not sure the tool is properly
grounded.
USE A SEPARATE ELECTRICAL CIRCUIT
tools. This circuit must not be less than #12 wire and
should be protected with a 15 Amp time delay fuse.
Before connecting the motor to the power line, make
sure the switch is in the OFF position and the electric
current is rated the same as the current stamped on the
motor nameplate. Running at a lower voltage will
damage the motor.
This tool is intended for use on a circuit that has a
receptacle like the one illustrated in FIGURE A.
shows a 3-prong electrical plug and receptacle that has a
grounding conductor. If a properly grounded receptacle is
(FIGURE B)
not available, an adapter
temporarily connect this plug to a 2-contact ungrounded
receptacle. The temporary adapter should be used only
until a properly grounded receptacle can be installed by
a qualified technician. The adapter
rigid lug extending from it that MUST be connected to a
permanent earth ground, such as a properly grounded
receptacle box. The Canadian Electrical Code prohibits
the use of adapters.
CAUTION:
In all cases, make certain the receptacle is
properly grounded. If you are not sure have a qualified
electrician check the receptacle.
A WARNING
This table saw is for indoor use only. Do not expose to
rain or use in damp locations.
If it will not
of the equipment grounding
for your
FIGURE A
can be used to
(FIGURE B)
has a
SAVE THESE INSTRUCTIONS
Fig. A
GUIDELINES FOR EXTENSION CORDS
USE ONLY 3-wire extension cords that have 3-prong
grounding piugs and 3-pole receptacles that accept
the tool's plug. Repair or repiace damaged or worn
cord immediateiy.
USE PROPER EXTENSION CORD.
extension cord is in good condition. When using an
extension cord, be sure to use one heavy enough to carry
the current your product will draw. An undersized cord will
result in a drop in line voltage and in loss of power which
will cause the tool to overheat. The table below shows the
correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next heavier
gauge. The smaller the gauge number, the heavier the
cord.
Be sure your extension cord is properly wired
good condition. Always replace a damaged extension cord
or have it repaired by a qualified person before using it.
Protect your extension cords from sharp objects,
excessive heat and damp or wet areas.
A WARNING
This tool must be grounded while in use to protect the
operator from electrical shock.
3-Prong Plug
Make sure your
and in

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents