150-402-100-03
Table 7. Span Status Fields and Descriptions
Field
Description
Time
Time of day when Span Status was checked.
Date
Date when Span Status was checked.
Alarms
Presence or absence of alarm conditions. See
Loopback
Indicates Off condition or identifies specific active loopback. See
Power Level
Indicates the HDSL Power Feed voltage mode: High or Low.
Margins
Indicates the excess signal to noise ratio at all HDSL ports, relative to a
10
First value is current margin.
Second value is minimum margin since last cleared.
Third value is maximum margin since last cleared.
N/A means that the margin is not available.
Pulse
Indicates the attenuation of the 2B1Q pulse from the distant end. HiGain
Attenuation
operates with pulse attenuations up to 28 dB. This value is related to the
cable pair's 196 kHz loss. The pulse attenuation is a more direct indication
of the loop attenuation to the 2B1Q signal than the 196 kHz loss.
INS Loss
Indicates the approximate attenuation of the HDSL loop at 196 kHz. It is
generated by multiplying the pulse attenuation by 1.25.
PPM Offset
Indicates the relative offset of the crystal oscillator in the HRU-402 from
the HLUs crystal oscillator. Any value between ± 100 is adequate.
HDSL 24
The number of one second intervals that contained at least one HDSL CRC
Hour ES
error. This value is a running total of the last 24 Hours.
HDSL 24
The number of seconds the HDSL loop was out of synchronization.
Hour UAS
DS-1 BPV
The number of seconds in which at least one bipolar violation was
Seconds (ES)
detected on the DS-1 input.
DS-1 UAS
The number of seconds during which the DS-1 input signal was absent
Count
(125 or more consecutive 0s).
Frame type
Type of DS-1 framing used on the input stream (SF, ESF, Unframed or No
Activity).
Code type
Type of DS-1 line coding used (AMI, B8ZS, AMI: Zero Byte Time Slot
Interface[ZBTSI] or B8ZS: ZBTSI). The latter two conditions indicate the
code type that is being received when HiGain is set to its ZBTSI mode. In
either the AMI or B8ZS DS-1 code mode, it displays the selected code as
opposed to the code type that is actually being received, which it displays
when the DS-1 CODE option is set to AUTO.
HRU-402 List 1 and List 3
-7
Bit Error Rate.
November 5, 1998
Using the Maintenance Terminal
Table
10.
Table
8.
33