Installation
2
Once the serial cable is connected to the Craft port (RS-232 dB-9
connector) on the HRU-402, connect the other end of the cable to the
9-pin COM port (RS-232) of the maintenance terminal
maintenance terminal is configured as Data Terminal Equipment (DTE).
Maintenance terminal
9-pin COM port
Interface cable
Figure 8. Connecting the HRU-402 to a Maintenance Terminal
3
Configure the maintenance terminal to the following communication
settings:
1200 to 9600 baud (9600 baud is recommended)
Parity: None
8 data bits
1 stop bit
Hardware Flow Control set to None
VT Terminal Emulation
24
HRU-402
November 5, 1998
150-402-100-03
(Figure
Craft port
HRU-402 List 1 and List 3
8). The