1) Drawer 1 Check

1 Check content
The solenoid of drawer 1 is turned on, and the drawer open
sensor value is sensed at every 100ms, and the state is dis-
played.
2 Display
Drawer 1 Check
Drawer Open Sensor
3 Terminating procedure
Press the Touch panel to terminate the check.

2) Drawer 2 Check

1 Check content
The solenoid of drawer 2 is turned on, and the drawer open
sensor value is sensed at every 100ms, and the state is dis-
played.
The display and the terminating procedure are the same as
Drawer 1 Check.

3-13 Printer Diagnostics

I/F loopback and printing tests of the printer are performed.
The following menu appears. Press the name of the test you want to
perform to execute its Diag program. When the Diag program is
terminated, the screen returns to the Printer Diagnostics menu.
Pressing the CANCEL key returns to screen to the Diag Menu.
Printer Diagnostics

Loop Back Check

Printer Print Check

1) Loop Back Check
1 Check
A LOOPBACK test on the built-in printer (UP-T80BP) interface
(logic channel 7 of RS232) is performed and the result is dis-
played. The test itself is the same as that for the RS232. The
difference in test specifications is as follows: The loopback signals
are for ER-DR, RS-CS, TXD-RXD only and the following LOOP-
BACK-Connectors are required.
CD
RD
SD
ER
GND
DR
RS
CS
CI
Fig.3-11. Wiring diagram of loopback connectors (UKOG-2356BHZZ)
2 Indication
The indication is the same as that for RS232 DIAGNOSTICS.
3 End
Press the PANEL to end the program.
:
OPEN (or CLOSE)
Cancel
1pin
2pin
3pin
4pin
5pin
6pin
7pin
8pin
9pin
2) Printer Print Check
1 Check
Send the signal to generate a receipt (by DIAG COMMAND) to
the UP-T80BP.

3-14. EFT (ER-02EF) Diagnostics

1) Procedure

1 Select "EFT Diag" in the DIAG MAIN MENU.
2 Power off.
3 The EFT starts up automatically by setting the whole 8-pin DIP
switch SW1 to OFF and then turning the main power switch ON.

2) Test

When powering up the EFT, the loop-back test of EFT CN's ER-DR,
ER-CI, and RS-CS is performed automatically.
Check the switch by turning on switch 1 to 8 of SW1 one by one.
Then, perform the sum check test of EFT ROM and the write/read
check of RAM.
Perform the same test as JOB300 for address 0000H, 0001H, 0002H,
0004H, 0008H, 0010H, 0020H, 0040H, 0080H, 0100H, 0200H,
0400H, 0800H, 1000H, 2000H, and 4000H of RAM.

3) End (display)

Normal end
DIAG0 (SELF TEST)
VHI27040R**1*
256K SRAM
Error end
In Loop Back Error
ER-DR LOOP ERROR
ER-CI LOOP ERROR
RS-CS LOOP ERROR
In Self Test Error
DIP SW ERROR
In ROM/RAM Error
VHI27040R**1*
256K SRAM
6 – 11