Magnetic Card Reader Diagnostics; Magnetic Card Reader Check; System Switch Diagnostics; System Switch - Sharp UP-5300 Service Manual

Pos terminal
Hide thumbs Also See for UP-5300:
Table of Contents

Advertisement

xi. Color pattern (256 colors)
Color pattern of 256 colors is displayed. The displayed colors
are the default pallet.
Arrange RAMDAC register No. 0 ∼ 255 from the upper left.
xii. Backlight OFF
The backlight is turned off without turning off the display.
xiii. Backlight ON
2
Terminating method
Press the space bar or Esc key to terminate and return to the
Serviceman's diagnostics menu.

3-13. Magnetic Card Reader Diagnostics

This test program reads the magnetic card based on the ISO7811/1-5
standard and displays the data.
Pressing the Esc key returns to the service diagnostics menu.

1) Magnetic Card Reader Check

1
Checking content
The test program reads tracks 1 and 2 of the magnetic card (UKOG-
6718RCZZ) based on the ISO7811/1 ∼ 5 standard, and displays the
data in ASCII code. There are two kinds of data patterns to be read.
TRACK 1: IATA pattern
76 character 7bit/character (Max. 79 character)
TRACK 2: ABA data pattern
28 character, 5bit/character (Max. 40 character)
To read the card data, the following setting is performed.
Mode set
46h is set to PSC2 channel 1 mode set register. (IATA, 6bit)
74h is set to PSC2 channel 2 mode set register. (ABA, 4bit)
Start mark set
45h is set to PSC2 channel 1 start mark register.
0Bh is set to PSC2 channel 2 start mark register.
Interrupt reset
Dummy data is written to PSC2 channel 2 start mark register.
Interrupt mask cancel 01h is written to PSC2 MCR mask
register to cancel mask.
In addition, setting for the PSC2 extension interruption is per-
formed.
When the card is scanned, the obtained data is written to the
FIFO buffer from the start mark to LRC in sequence. Then, the
card data is read by interrupt process.
After reading data, the FIFO buffer is reset.
2
Display
MCR (Magnetic Card Reader) Check
TRACK1:
SHARP TEST CARD 0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789 UKOG-6718RCZZ
TRACK2:
0123456789012345678901234567
The above display is made when the card (UKOG6718RCZZ) is
passed through the MCR. In case of an error, the error code is
displayed as follows:
Magnetic Card Reader Check
TRACK 1 : BUFFER EMPTY
TRACK 1 : MCR ERROR
TRACK 2 : BUFFER EMPTY
TRACK 2 : MCR ERROR
3
Terminating method
Press the Esc key to terminate the test and return to the
Serviceman's diagnostics menu.

3-14. System Switch Diagnostics

The system switch information of the main PWB is displayed.
Pressing the Esc key returns to the serviceman diagnostics menu.

1) System Switch

1
Checking content
The system switch reads I/O address 7F0H every 10ms to display
the value of bit 0 ∼ 7. The relationship between the bit and SW is
as shown in the table below.
Bit
7
6
7F0H
SW8
SW7
2
Display
System Switch Diagnostics
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
X
X
X
Each SW data is displayed at X. If bit data is "1," the display is
"OFF". If bit data is "0," the display is "ON".
3
Terminating method
Press the Esc key to terminate the test and return to the
Serviceman's diagnstics menu.

3-15. Drawer Diagnostics

The drawer open and sensor test are executed.
The following menu is displayed. The highlighted cursor is moved by
the cursor keys (UP ↑ and DOWN ↓) of the AT keyboard. Move the
cursor to the desired item, and press the Enter key to execute the
selected diagnostics program. When the selected diagnostics pro-
gram is completed, the display returns to the menu screen. Pressing
the Esc key returns to the service diagnostics menu.
Drawer Diagnostics

Drawer 1 Check

Drawer 2 Check
1) Drawer 1 check
1
Checking content
The drawer 1 solenoid is turned on and the drawer open sensor
value is sensed at every 100ms and the state is displayed.
When Drawer 1 and Drawer 2 are connected, "CLOSE" is dis-
played only when both the drawers are closed.
4 – 11
Displayed when TRACK1 EMPTY CODE is returned.
Displayed when TRACK1 ERROR CODE is returned.
Displayed when TRACK2 EMPTY CODE is returned.
Displayed when TRACK2 ERROR CODE is returned.
5
4
3
2
SW1
SW2
SW3
SW4
X
X
X
X
X
1
0
SW5
SW6