Display
MCR (Magnetic Card Reader) Check
TRACK1:
SHARP TEST CARD 0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ0123456789 UKOG-6718RCZZ
TRACK2:
0123456789012345678901234567
The above display is made when UKOG6718RCZZ is passed
through the MCR. In case of an error, the error code is displayed
as follows:
Magnetic Card Reader Check
TRACK 1 : BUFFER EMPTY
TRACK 1 : MCR ERROR
TRACK 2 : BUFFER EMPTY
TRACK 2 : MCR ERROR
Terminating method
Press Esc key to terminate the test.

3-14. System Switch Diagnostics

System switch information of the main PWB is displayed.
Pressing Esc key returns to the serviceman diagnostics menu.

1) System Switch

Check content
The system switch reads I/O address 7F0H every 10ms to display
the value of bit 0
7. The relationship between the bit and SW is
as shown in the table below.
Bit
7
6
5
7F0H
JP8
JP7
SW1
Display
System Switch Check
JP8 JP7 SW6 SW5 SW4 SW3 SW2 SW1
X
X
X
X
X
X
Each SW data is displayed at X. If bit data is "1," the display is
"OFF". If bit data is "0," the display is "ON".
Terminating method
Press Esc key to terminate the test.

3-15. Drawer Diagnostics

Drawer open and sensor test are executed.
The following menu is displayed. The highlighted cursor is moved by
the cursor keys (UP
and DOWN ) of the AT keyboard. Move the
cursor to the desired item, and press Enter key to execute the se-
lected diagnostics program. When the selected diagnostics program
is completed, the display returns to the menu screen. Pressing Esc
key returns to the service diagnostics menu.
Displayed when TRACK1 EMPTY CODE is returned.
Displayed when TRACK1 ERROR CODE is returned.
Displayed when TRACK2 EMPTY CODE is returned.
Displayed when TRACK2 ERROR CODE is returned.
4
3
2
1
SW2
SW3
SW4
SW5
SW6
X
X
Drawer Diagnostics

Drawer 1 Check

Drawer 2 Check

1) Drawer 1 check
Check content
Drawer 1 solenoid is turned on and the drawer open sensor value
is sensed at every 100ms and the state is displayed.
When Drawer 1 and Drawer 2 are connected, "CLOSE" is dis-
played only when both the drawers are closed.
Display
Drawer 1 Check
Drawer Open Sensor
Terminating method
Press Esc key to terminate the test.
2) Drawer 2 Check
Check content
Drawer 2 solenoid is turned on and the drawer open sensor value
is sensed at every 100ms and the state is displayed.
When Drawer 1 and Drawer 2 are connected, "CLOSE" is dis-
played only when both the drawers are closed.
0
Display
Same as Drawer 1.
Terminating method
Same as Drawer 1.

3-16. Pole Display Diagnostics

The pole display includes a microprocessor inside and makes com-
munication with the host by RS232 conforming interface.
PSC2 UART4 is used on the main body side.
Communication conditions are as follows:
Data length:
Parity (Yes/No): No
Baud rate:
Check content
The test patterns are displayed in the sequence shown below.
Pressing the space bar moves to the next pattern.
i. The following test patterns are displayed.
4 – 15
: OPEN (or CLOSE)
8 bit
9600bps