ADC HiGain H2TU-R-402 Quick Installation

ADC HiGain H2TU-R-402 Quick Installation

List 5e remote unit

Advertisement

Quick Links

T
H2TU-R-402
HE
The H2TU-R-402 remote unit is the customer premise side of a transmission system.
The HiGain HDSL2 product family is fully compliant with the HDSL2 standard and
ANSI T1/E1.4. Providing full-rate T1 access using just a single copper pair, HDSL2
is a cost-effective solution that offers an open architecture. The open architecture
inherent in HDSL2 guarantees interoperability, allowing simple and economic
accommodation of network growth.
HiGain HDSL2 products provide 1.552 Mbps transmission on one unconditioned
copper pair over the full Carrier Service Area (CSA) range. The CSA includes loops
up to 12,000 feet of 24 American Wire Gauge (AWG) wire or 9,000 feet of 26 AWG
wire, including bridged taps.
F
EATURES
• Front panel status LEDs and craft port
• Performance report messaging (PRM) support
• Ultra-low wander
• Bit Error Rate (BER) alarm options
• Line or locally powered with sealing
• Bipolar Violation Transparency BPVT) options
current option
• Selectable DS1 pre-equalizer
• Digial Data Service (DDS) latching loopback
• Full-duplex HDSL2 transmission on one
• Enhanced loopback commands controlled by the
pair at 1.552 Mbps
• Metallic loopback self-tests
• Report menu option for downloading data to a file
• HiGain maintenance screens for remote
• Sinks 10 mA of sealing current from the line unit for
provisioning, performance monitoring,
inventory, and troubleshooting
S
PECIFICATIONS
Operating Temperature
-40 °F to +149 °F (-40 °C to +65 °C)
Operating Humidity
5% to 95% (non-condensing)
Line or Local Power Consumption
5 Watts
Secondary surge and power cross-protection on all SD1
Electrical Protection
and HDSL2 ports
Mounting
Any 400 or 200 mechanics shelf
1.552 Mbps Overlapped Pulse Amplitude Modulated
HDSL2 Line Rate
Transmisstion with Interlocking Spectra (OPTIS)
+16.8 dBm ±0.5 dB at 135 Ω
HDSL2 Output
35 dB at 196 kHz, 135 Ω
Maximum Provisioning Loss
DS1 Line Rate
1.544 Mbps ±200 bps
Alternate Mark Inversion (AMI), Bipolar with 8-Zero
DS1 Line Format
Substitution (B8ZS) or Zero Byte Time Slot Interchange
(ZBTSI)
Extended SuperFrame (ESF), SuperFrame (SF), or
DS1 Frame Format
Unframed (UNFR)
LBK option
local power applications
I
NSTALLATION
H2TU-R-402
Wear an antistatic wrist strap when installing the H2TU-R.
Avoid touching components on the circuit board.
1
Align the H2TU-R with the enclosure slot guides and slide the unit in.
Push the unit back until it touches the backplane card-edge connector.
2
Place your thumbs on the front panel and push the H2TU-R into the
card-edge connector.
When local power is applied to this unit, it automatically
provides a resistive termination at its HDSL2 port. This
termination will sink 10 mA of sealing current when
connected to a list 3E or higher line unit.
Remote enclosure
Þ
Continued

Advertisement

loading

Summary of Contents for ADC HiGain H2TU-R-402

  • Page 1 H2TU-R-402 The H2TU-R-402 remote unit is the customer premise side of a transmission system. NSTALLATION The HiGain HDSL2 product family is fully compliant with the HDSL2 standard and ANSI T1/E1.4. Providing full-rate T1 access using just a single copper pair, HDSL2 is a cost-effective solution that offers an open architecture.
  • Page 2 SF LED = Solid green Indicates Super Frame (SF). The LED blinks once per second when a frame error onfig Standard configuration options, ADC options, date and time setting, and a reset option. occurs. nventory Product information about the various devices that are in the system and lists circuit OFF Indicates unframed or no signal.