Cleveland SteamCraft 24-CDP-10 Specification Sheet page 2

Steamcraft generator style high speed convection steamers
Hide thumbs Also See for SteamCraft 24-CDP-10:

Advertisement

TOTAL CAPACITY
(2 Compartments)
10 — 12˝ x 20˝ x 2
1
˝ Cafeteria Pans or
2
20 — 12˝ x 20˝ x 1˝ Cafeteria Pans or
26 — 12˝ x 20˝ x 4˝ Cafeteria Pans
DIRECT STEAM
Steam supply:
Furnish
3
˝ IPS minimum line.
4
20 to 50 psi minimum required.
For pressures between 50 to 120 psi, on additional
Pressure Reducing Valve must be specified.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL, ULC and UL/NSF#4.
UTILITY CONNECTIONS
Electrical Supply
A
B
Water Supply for Condenser
3
˝ Dia. NPT
8
Steam Supply: 0.75˝ Dia.
C
ELECTRIC
115V - 1 Phase
Controls - 51 Watts
Drain: 1.50˝ Dia.
D
COLD WATER
DRAINAGE
C
35 psi minimum
1
1
˝ Dia.
2
60 psi maximum
Do not connect other units
3
˝ Dia. NPT for
to this drain.
4
C
Condenser
Drain must not be located
beneath the steamer itself.
No PVC pipe for drain.
Each Compartment has
capacity for:
• Five, 12˝ x 20˝ x 2
1
˝ deep
2
Cafeteria Pans.
WATER QUALITY
REQUIREMENTS
The quality of water varies
greatly from region to region.
Steam equipment generators
must be drained daily and
chemically descaled periodically
to ensure proper operation. To
minimize
service
problems
caused by the accumulation of
minerals and chemicals in water
review the following quality
guidelines with a local water
treatment specialist. Inlet water
that is beyond these specified
guidelines should be treated to
achieve these acceptable limits.
Total Dissolved Solids less than
60 ppm, Alkalinity less than 20
ppm, Silica less than 13 ppm,
pH factor greater than 7.5,
Chlorine less than 30 ppm.
CLEARANCE
D
Right - 3", Left - 3", Rear - 3"
(12" on control side if
adjoining wall or
equipment is over 30"
high for service access)
Contact factory for
variances to clearances.
(NOT TO SCALE)
IV
SECT.
Litho in U.S.A.
22
PAGE
0707