Open; Scan - Agilent Technologies E1364A User Manual

Agilent e1364a 16-channel form c switch module 75000 series b
Table of Contents

Advertisement

OPEN?

Comments
Example

SCAN

Parameters
Comments
Example
54 Agilent E1364A Form C Switch Command Reference
[ROUTe:]OPEN? <channel_list>
queried. channel_list has the form (@ccnn) (see [ROUTe:]OPEN for
definition). The command returns 1 if channel(s) are open or returns 0 if
channel(s) are closed.
Query is Software Readback: The ROUTe:OPEN? command
returns the current software state of the channels specified. It does
not account for relay hardware failures. A maximum of 127 channels
at a time can be queried for a multi-module switchbox.
Query Channel Open State:
This example opens channels 100 and 213 of a two-module switchbox and
queries channel 213 state. Since channel 213 is programmed to be open, 1 is
returned.
OPEN (@100,213)
OPEN? (@213)
[ROUTe:]SCAN <channel_list>
channel_list has the form (@ccnn) where cc = card number (01-99) and nn
= channel number (00-15).
Parameter Name
<channel_list>
Defining Scan List: When [ROUTe:]SCAN is executed, the channel
list is checked for valid card and channel numbers. An error is
generated for an invalid channel list.
Scanning Channels: You can scan single channels (@ccnn);
multiple channels (@ccnn,ccnn,...); sequential channels
(@ccnn:ccnn); groups of sequential channels
(@ccnn:ccnn,ccnn:ccnn); or any combination.
Scanning Operation: When a valid channel list is defined,
INITiate[:IMMediate] begins the scan and closes the first channel in
the channel list. Successive triggers from the source specified by
TRIGger:SOURce advance the scan through the channel list.
Stopping Scan: See ABORt.
Related Commands: TRIGger, TRIGger:SOURce
*RST Condition: All channels open.
Scanning Using External Device:
See Chapter 4, "Example: Scanning With External Devices" or "Example:
Scanning Using Trig Out and Event In Ports" for example scanning
programs using external instruments.
returns the current state of the channel(s)
Open channels 100 end 213
Query channel 213 state
defines the channels to be scanned.
Parameter Type
Range of Values
numeric
cc00 - cc15
Chapter 5