Figure 11-104. Fuel Line Hose Routing Outside Leg
of Air Cleaner Bracket.
3. Torque the two elbow mounting screws to
7.3 N·m (65 in. lb.). See Figure 11-105. Then torque
the eight valve cover mounting screws to 6.2 N·m
(55 in. lb.) in the sequence shown in Figure 11-107.
Figure 11-105. Torquing Elbow Mounting Screws.
Figure 11-106. Torquing Valve Cover Screws.
1
4
Figure 11-107. Torque Sequence.
4. If removed, install the rain cap and secure with
the clamp. Check the position of the dust ejector,
it should face downward. Adjust the end cap
position as required. See Figure 11-108.
Figure 11-108. Dust Ejector Valve and Rain Cap
Position.
5. Connect the wires for the audible alarm, if used.
Install Radiator Assembly
1. Reassemble the components of the radiator
assembly, including upper and lower radiator
hoses. Rubber lubricant may be applied to the
inner surfaces of the hoses to make installation
easier. Secure with the hose clamps. The radiator
subassembly should look as shown in Figure
11-109.
Section 11
Reassembly
3
2
11
11.29