applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). No restrictions on product
configurations except for rotating hard drives. PCI cards must be rated for continuous operation with 60°C cooling air. Not rated for
operation over 3,030 m (10,000 ft).
2
Fan failure might reduce performance
Table 10: Extended Edgeline specifications
Table 10: Extended Edgeline specifications
Specification
Specification
1
Temperature range
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Relative humidity (noncondensing)
Operating
Non-Operating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 304.8 m (1.8°F per 1,000 ft) to 3,048 m (10,000 ft)
is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour).
Value
Value
0°C to 55°C (32°F to 131°F)
-30°C to 60°C (-22°F to 140°F)
8% to 90% at 28 °C (82.4°F) maximum wet bulb
temperature
5% to 95% at 38.7 °C (101.7°F) maximum wet bulb
temperature
Environmental specifications