6. Plasma panel replacement method
To replace the plasma panel (finished), place the unit on the servicing stand, remove the
front frame (finished), and attach the panel, being careful not to scratch the plasma panel
surface.
1. Remove the rear cover.
2. Remove the P module.
A. Remove the couplers (P2, P5, P9, P11, P12, P23, P25, P27)
connected to the P module.
B. Remove the P module fastening screws (×5) and remove the P
module.