Verify The Fans - Dell Data Domain DD6300 Manual

Hide thumbs Also See for Data Domain DD6300:
Table of Contents

Advertisement

4. Rotate the storage processor extraction levers upwards until the storage processor retracts fully into place and the storage
processor extractors snap into place (2).
NOTE:
The extractors snapping into place is not guaranteed. Press the release buttons, and then swing the extractors
into place. Then, let go the release buttons. If testing when the SP is fully seated, attempt to swing out the extractors
without releasing them.

Verify the fans

Steps
1. Enter the enclosure show fans command to check the status of the enclosure fans.
# enclosure show fans 1
Enclosure
Description
---------
-----------
1
FAN 0A
FAN 0B
FAN 1A
FAN 1B
FAN 2A
FAN 2B
FAN 3A
FAN 3B
FAN 4A
FAN 4B
FAN 5A
FAN 5B
---------
-----------
Check the Status column to confirm that all of the fans in Enclosure 1 are OK.
2. Enter the alerts show current command and confirm that the system has cleared the alert for the failed fan. It may
take one to two minutes after the fan replacement before the system clears the alert.
# alerts show current
No active alerts.
14
Field Replaceable Units
Level
Status
------
------
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
medium
OK
------
------

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Data domain dd6800Data domain dd9300