Kohler K-5402T-0 Homeowner's Manual page 63

Veil intelligent toilet
Table of Contents

Advertisement

Available languages
  • EN

Available languages

12.UV sterilization stop
13.No display on
remote
14.Remote unable to
control toilet.
15.Seat temp is low
when seated.
1 1 6 6 . . No water sup
from inlet valve.
17.No water flush when A. Wrong adjusting board and screw rod installation.
press FLUSH FULL or
FLUSH ECO button.
1 1 8 8 . . Water level is
high or too low.
19.Toilet leak.
If you're going to service the toilet, you should observe the following rules:
Turn off switch on terminal box (refer to owners guide Page 52 diagram).
If it is necessary, open water supply valve.
Please cut off power supply before servicing terminal box.
Kohler Co.
A. Customer sits on seat.
B. The seat is covered by an object or the seat is
wet.
A. Battery runs out.
B. Wrong battery installation.
C. Remote has not been awakened yet.
A. Battery runs out.
B. Remote and toilet distance is too far.
C. Toilet power is not ON.
D. Toilet is under OFF mode.
E. Toilet and remote is not connected.
A. Seat temp is OFF.
B. Energy saving mode.
A. Water inlet valve is not OPEN.
B. Water inlet float is covered by other parts.
C. Water inlet valve float is stacked by other objects.
B. Discharge valve leveler and barb is not connected.
A. Water inlet valve float is not adjusted properly.
A. Foreign objects block water inlet valve float
when water enters water tank; unable to stop water;
water leak from water discharge valve overflow pipe.
B. Foreign objects on water sealing piece.
A. Please close cover and reactivate UV
sterilization and close toilet cover.
B. Remove objects or wipe seat.
A. Change new battery.
B. Re-install battery correctly.
C. Touch remote screen.
Approach to toilet or seated
Press remote awaken button
A. Refer to owners guide "Remote battery use
and replace" section toreplace battery.
B. Refer to owners guide "Remote to toilet
communication" section and move remote
closer to toilet.
C. Please connect toilet power supply.
D. Turn on switch to terminal box (refer to
owners guide page 52 diagram).
E. Refer to owners guide "Remote to toilet
communication" section, connect toilet to
remote.
A. Refer to owners guide remote guide within
the manual for temp setting.
B. Refer to owners guide remote guide within
the manual to exit energy saving mode.
A. Open water inlet valve.
B. Adjust other parts to avoid any contact with
float during process.
C. Clean float by water.
A. Re-install screw rod.
B. Re-install barb on discharge valve lever
and snap in.
A. Adjust water level again.
A. Adjust other parts to avoid any contact with
float during process.
B. Remove foreign objects on water seal piece.
63
1302892-T01-B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents