Panasonic AG-DV2500P Service Manual page 281

Hide thumbs Also See for AG-DV2500P:
Table of Contents

Advertisement

Measuring
No.
Item
instruments &
Input signals
7
NTSC Y/C IN
WFM (NTSC) or
REC C level
oscilloscope
adjustment
Y/C IN.
(SETUP OFF)
NTSC 100%
color bar
(SETUP 0%)
8
NTSC LINE IN
WFM (NTSC) or
REC Y level
oscilloscope
adjustment
LINE IN.
(SETUP OFF)
NTSC 100%
color bar
(SETUP 0%)
9
NTSC LINE IN
WFM (NTSC) or
REC SETUP
oscilloscope
level adjust-
LINE IN.
ment
NTSC 100%
(SETUP OFF)
color bar
(SETUP 0%)
Adjustment without setup
3-10
Measuring point
Mode
Adjustment parts (
Adjustment level (
EE
C OUT (Y/C jack) (75
ADJUST
terminated)
MENU, 217.
[PLAY] and [STOP]
YC REC C LEV
buttons
(S OFF)
908 mVp-p
(RED)
908mVp-p
836mVp-p,
adjustment with
setup
EE
Y OUT (Y/C jack) (75
ADJUST
terminated)
MENU, 218.
[PLAY] and [STOP]
LE REC Y LEV
buttons
(S OFF)
100 IRE
(714 mVp-p)
100 IRE
(714mVp-p)
EE
Y OUT (Y/C jack) (75
ADJUST
terminated)
MENU, 219.
[PLAY] and [STOP]
LE REC ST LV
buttons
(S OFF)
0 ± 6 mV of the
pedestal level
±
0
6mV
of the pedestal level
(Note)
Adjustment with setup
(
)
)
Adjustment procedure
)
(1)Set the INPUT SELECT SW to LINE or Y/C.
(2)Select ADJUST MENU No. 217, "YC REC C
LEV (S OFF)".
(3)Adjust so that the RED color levels are as speci-
fied.
(4)Press the [SET] button to store the adjustment
data.
Reference:
If 7.5% signal setup should be used, the
same effect as this adjustment can be ob-
tained by adjusting the color level to 836
mV p-p (100% color).
(1)Set the INPUT SELECT SW to LINE or Y/C.
(2)Select ADJUST MENU No. 218, "LE REC Y LEV
(S OFF)".
(3)Adjust so that the level from the pedestal to
100% WHITE is as specified.
(4)Press the [SET] button to store the adjustment
data.
(1)Set the INPUT SELECT SW to LINE or Y/C.
(2)Select ADJUST MENU No. 219, "LE REC ST
LV (S OFF)".
(3)Adjust so that the setup level is as specified.
(4)Press the [SET] button to store the adjustment
data.
(5)Check ADJUST MENU No. 218, "LE REC Y LEV
(S OFF)". If it is deviated, adjust it again.
Reference:
If 7.5% signal setup should be used, the
same effect as this adjustment can be ob-
53.6mV
tained by adjusting the setup level to 53.6
±
ı
6mV
mV ± 6 mV
.
Note:
Adjust the setup level by decreasing it from + side,
and stop decreasing when it just reaches 0.