Operation Keys

Type
Horizontal mounting
Vertical mounting
Adjustable mounting
(Horizontal)
Adjustable mounting
(Horizontal/Vertical)

Specifications

Standards and EC Directives
Applicable EC Directives and Standards
• Machinery Directive
• Low Voltage Directive
• EN1088
• EN60204-1
• GS-ET-19
Approved Standards
Agency
Standard
TÜV SÜD
EN60947-5-1 (approved
direct opening)
UL (See note 2.)
UL508, CSA C22.2 No.14
CQC (CCC)
GB/T 14048.5
Note: 1. Consult your OMRON representative for details.
2. Approval for CSA C22.2 No. 14 is authorized by the UL
mark.
D4NL
Model
D4DS-K1
D4DS-K2
D4DS-K3
D4DS-K5
Approved Standard Ratings
TÜV (EN60947-5-1)
Item
Rated operating current (I
Rated operating voltage (U
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
File No.
UL/CSA (UL508, CSA C22.2 No. 14)
(See note 1.)
A300
Rated
E76675
voltage
Contact your
120 VAC
OMRON
representative
240 VAC
Solenoid Coil Characteristics
Rated operating
voltage (100% ED)
Current consump-
tion
Insulation
Indicator Characteristics
Rated voltage
Current leakage
Color (LED)
Utilization
category
)
3 A
e
) 240 V
e
protection device. This fuse is not built into the Switch.
Carry current
Current
Make
10 A
60 A
30 A
Item
24 VDC
24 VDC +10%/
15%
Approx.
200 mA
Class F (130C max.)
Item
10 to 115 VAC/VDC
Approx. 1 mA
Orange
AC-15
DC-13
0.27 A
250 V
Volt-amperes
Break
Make
Break
6 A
7,200 VA 720 VA
3 A
110 VAC
230 VAC
110 VAC 10% 230 VAC 10%
Approx. 50 mA Approx. 30 mA
LED
G-155