In this test the unit should generate a 300 Hz tone and output on all the outputs.
If [PAGE >] or [<PAGE] is pressed then the display should cycle through the following
outputs in incrementing or decrementing order based on the button (PAGE> is increase
and <PAGE will decrease).
All
MainL
MainR
AuxL
AuxR
Pressing [STOP] will stop the test and jump back to the diagnostic menu.
10. Test 8: MIDI Test
The LCD should show display the following:
Before executing the test, a MIDI cable should be connected from the MIDI Out to the
MIDI In. When the test is executed, 16 different MIDI messages should be sent out the
MIDI output. The same MIDI input messages should be detected. If all the input
messages are the same as was sent, then the LCD should display "Passed", otherwise the
LCD should show "Failed".
Or
11. Test 9: Flash Test
The LCD should show display the following:
Upon the user pressing [PLAY] the system will write/read a small reserved section of the
Flash and verify the results:
Diags
MIDI
MIDI
Passed
MIDI
Failed
Diags
Flash