 Inspect all electrical cords; repair or replace any that are cut, worn, or bare.
 Ensure all winch cables are in good condition and centered on each pulley. Do not use if cables are
kinked or beginning to unravel.
 Check oil, coolant, and fuel levels. For more information, refer to
 Ensure engine battery connections are secure.
 Turn the battery disconnect switch on, if equipped.
 Check the engine fan belt tension and condition.
 Check the engine fan belt guard.
 Check the engine exhaust system for loose or rusted components.
 Ensure all covers are in place and secure.
 Ensure the emergency stop switch is pulled out.

EMERGENCY STOP SWITCH

The unit is equipped with one emergency stop switch. For location of the emergency
stop switch, refer to
"Component Locations" on page
labeled "EMERGENCY STOP." The switch can be accessed and activated with all
doors closed and locked.
Activate the emergency stop switch by pushing th button in until it locks down. This
will open the fuel circuit, shutting down the engine. The switch will remain locked until
it is pulled out.
Use the emergency stop switch only when the unit must be shut down immediately. For any

STARTING THE UNIT

1. Check that the main circuit breaker and individual
circuit breakers for each of the lights are in the "OFF/
O" position.
Note: When the red "TURN MAIN BREAKER OFF" light
is illuminated, the main circuit breaker must be turned
OFF (O).
2. Turn the key on the Control Power switch to the left
"GLOW PLUG" position and hold the key in place for
five seconds, or until the glow plug indicator turns
red. As soon as it is glowing, turn the key to the right
"START" position and hold it until the engine cranks and starts running. Release the key, it will move to the "RUN"
position.
Note: For cold weather conditions, refer to the engine operator's manual for appropriate glow plug interval.
ACTIVATE GLOW PLUG
OFF
GLOW
PLUG
Do not crank the engine longer than 10 seconds at a time. If the engine will not start, wait
20
other shut down, refer to
"Shutting Down the Unit" on page
CRANK ENGINE TO START
RUN
GLOW
PLUG
START
"General Maintenance" on page
15. The red button is clearly
CIRCUIT BREAKERS
OFF
GLOW
RUN
PLUG
START
22.
I
I
I
I
O
O
O
O
RELEASE KEY
OFF
RUN
START
00203
26.
00230
00202