TROUBLESHOOTING
※ Self-diagnostics check list
LED
Item
F
R
Deodorizer-
FAN Error
Panel ↔ Main
Communication
Main - Inverter
Communication
I/O Expander
Communication
The F
compartment
abnormal
hightemperature
indicator blinks
The R
compartment
abnormal
hightemperature
indicator blinks
Comp
starting
Failure
Error
IPM Fanlt
Error
Comp
Abnormal
current
Detection
Error
Motor
Locked
Over RPM
Error
Comp
under
voltage
Error
Comp
over
voltage
Error
RS6500KC(RH62K)-FSR-160106.indd 52
Trouble contents
Display error during operation of
applicable fan motor : Feed back
signal line contact error, motor wire
separation, motor error
Display pc - Er in the panel with
alarm : MICOM MAIN ↔ PANEL
Error
communication error.
Display 44Er in the panel :
Inverter MICOM ↔ Main MICOM
Error
communication error.
Display 46Er in the panel :
I/O Expander ↔ Main MICOM
Error
communication error.
When the freezer temperature
is abnormally high or the
freezer door is open for a
certain period of time and the
freezer temperature increases,
the freezer display blinks.
When the freezer temperature
is abnormally high or the fridge
door is open for a certain
period of time and the fridge
temperature increases, the
fridge display blinks.
When the Compressor fails
starting
When there is a IPM Fault error
When there is abnormal current
detected at the Compressor
When there is a Compressor
restriction error
When there is a low voltage
error
When there is a over voltage
error
F
Diagnostic method
The voltage of MAIN PCB CN52
2PIN - 3PIN shall be between
7V~12V
Actually, If there is not a problem,
it is desirable to replace Main and
Panel PCB With the oscilloscope
after a cable problem confirming.
Actually, If there is not a problem,
it is desirable
to replace Main and Inverter PCB
With the
oscilloscope after a cable problem
confirming.
It is desirable to replace Main
PCB.
The temperature has been
abnormally increased. Check
if the door has been open
for a long time or if hot
food has been stored in the
compartment. If the reason for
the error is removed, the error
code disappears after a pre-
determined period of time.
Check if door has been
open for a long time or if hot
food has been stored in the
compartment. If the reason for
the error is removed, the error
code disappears after a pre-
determined period of time.
Check if there is a short
between compressor
terminals. Check IPM Voltage
[Under 13.5V] Check if there
is a short between IPM Pins
[#1~33]
Check the Compressor and
the Cycle
Check the Compressor
connections Check the voltage
of Resistance of R308
[0.09Ohm] Check the
Compressor and the Cycle
Check the voltage of
Resistance of R308 [Short/
Open] Check the voltage
of both of C103 terminals
[Unstable Voltage] Check the
Compressor and the Cycle
Check the voltage of
Resistance of R513 [Short/
Open]
Check the voltage of
Resistance of R501, R505,
R509 [Short/Open]
R
F
52
Image
R
2016. 1. 7.
11:04