PRODUCT SPECIFICATIONS
2-3-1. Electric Parts Specification
Items
Model
Compressor
Freezer
Condenser
Desiccant
Capillary tube
Refrigerant
THERMISTOR
(F-SENSOR)
502AT
THERMISTOR
(R-SENSOR)
502AT
Initial defrosting cycle (simultaneous
defrosting of F and R)
Defrosting cycle of freezing component
Defrosting cycle of cold component
Idle duration
F defrosting
Sensor
R defrosting
Sensor
Bimetal (F)
Bimetal (R)
RS6500KC(RH62K)-FSR-160106.indd 12
Type
Drive mode
Charged oil
Freezer
compartment
Cold compartment
Freezing compartment
Cold compartment
Section
Strong (°C)
Intermediate (°C)
-20.5
Weak (°C)
Section
Strong (°C)
Intermediate (°C)
Weak (°C)
Type
Specification
Type
Specification
Type
Operating
temperature (°C)
Type
Operating
temperature (°C)
Specification
RH62*
NF34H9131AM
NC4EVA5ALN
INVERTER
SUNUSO-2GSD(250cc)
SPLIT FIN TYPE
WIRE TYPE
Forced and spontaneous convection type
Molecular sieve XH-9
ID0.85 x L4000
ID0.85 x L2650
R-600a
OFF
ON
-24
-22
-18.5
-16
-14
OFF
ON
0
3
1.5
4.5
6
8
6 hours±10 minutes
12 to 77 hours (varying dependent upon operation conditions)
12 to 77 hours (varying dependent upon operation conditions)
Thermistor (DTN-C502)
5.0 ㏀ at 25°C
Thermistor (DTN-C502)
5.0 ㏀ at 25°C
Bimetal thermostat (BT-121-M)
On: 40, Off: 60
12
RH58*
NC4EVA5ALN
OFF
ON
-24
-22
-20.5
-18.5
-16
-14
OFF
ON
0
3
1.5
4.5
6
8
-
-
-