PRODUCT SPECIFICATIONS
2-3-2. Electric Component
Defrosting heater in
freezing compartment
Defrosting heater in
cold compartment
Home bar heater
(cold compartment)
Door Heater (Freezing Compartment, Optional)
Door heater
(cold compartment)
Damper heater
Bimetal for preventing overheating of defrosting
heater in freezing compartment
Bimetal for preventing overheating of defrosting
heater in cold compartment
OLP
Cooling fan motor in freezing compartment
Cooling fan motor in cold compartment
Compressor cooling fan motor
Motor-driven damper
(True-taste chamber)
Freezing compartment lamp
Cold compartment lamp
Door reed switch (home-bar)
RS6500KC(RH62K)-FSR-160106.indd 13
Items
Model
Power supplying during
freezing compartment
defrosting
Power supplying during
cold compartment
defrosting
Ambient humidity sensor
interlocking
Icemaker heater
Dispenser heater
Water pipe heater
Ambient humidity sensor
interlocking
Kept tumed on
Noise filter
Type
Operating temperature
(°C)
Shutdown temperature
(°C)
Motor step valve
DC valve
Door reed switch
Power cord
Grounding screw
Specification
RH62K*
AC 120V 200W,
or AC 230V 200W
-
-
-
-
DC 12V
-
17W
Thermostat (BT-121-M) On: 40°C, Off: 60°C
5.0 ㏀ at 25℃
DC 12V, DREP3030LD
DC 12V, DRCP8020LA
DC 12V, 700mA
-
DC 12V 2.39W * 1EA
DC 12V 4.22W * 1EA
DC 200V 0.5A
AC 250V 10A or 16A
BSBN (BRASS SCREW)
13
RH58K*
-
-
AC 120V 145W or AC 230V 145W
AC 120V 6W or AC 230V 6W
AC 120V 5.4W or AC 230V 4.6W
AC 120V 2W or AC 230V 2W
DC 12V
-
17W
-
-
-
-
-
DC12V, ARES2120RB
-
DC12V, ARCS2088LA
-
DC 12V, 300mA
-
2016. 1. 7.