10. AC ADAPTOR
(1) Input voltage
(2) Input current
(3) Rated output
(4) Efficiency
(5) Ripple and noise voltage
(6) Insulation test
(7) Leakage current
(8) Temperature rise
(9) Over voltage protection
(10) Overload protection current
(11) No load power consumption
(12) Safety standard
(13) Size
(14) Case material
(15) Cable
(16) Plug
(17) Polarity
(18) Weight
11. EMI STANDARD
VCCI Class B
FCC Class B
EN55022
100V ~ 240V AC (50/60 Hz)
250 mA
9V ±5%
65% or more (AC 100V/50 Hz full load)
70% or more (AC 240V/50 Hz full load)
Less than 150 mVp-p (9 VDC)
More than 100M ohm
(DC 500V, 1 minute, between primary and secondary circuit and chassis)
0.25 mA or less (AC 240V/50 Hz)
45K or less on case surface (100 VAC/50 Hz full load @25°C)
120% - 150%
1.8 - 3.5A (AC 100-240, 25°C)
3W or less (AC 240V, 25°C)
UL, C-UL, PSE (10AD-JU)
VDE, GS, CE (10AD-E)
10AD-JU - 75 mm (L) × 50 mm (W) × 30 mm (H)
94V-1
1828.8 mm UL2468#22 × 2C
3.5 × 1.3 × 9.5S
Center "+"
104 g ±5g
— 78 —