ESC c5 n
[Function]

Enabling/Disabling Panel Switches

[Code]
<1B>H<63>H<35>H<n>
[Range]
{0 =< n =< FF(Hex)}
[Outline]
Selecting the LF switch valid/invalid.
• "n" is valid only in the lowest bit (n0).
[Caution]
• When the panel switch is disabled with this command, the LF switch is disabled.
• When LF switch is set to Invalid, it cannot be cleared by the Initialize command
[Default]
The initial value of n is "0".
[Sample Program]
PRINT #1, CHR$ (&H1B) + "c5" + CHR$ (0); ......When enabling the LF switch
PRINT #1, CHR$ (&H1B) + "c5" + CHR$ (1); ......When disabling the LF switch
n (Hex)
0
LFSW valid.
1
LFSW invalid.
Therefore, the paper cannot be fed by operating the LF switch.
(ESC @) but is cleared by turning power off.