Diagnostics; Diagnostics Mode - Fisher & Paykel CleanSmart WL8060P1 Service Diagnostic Manual

Top load washing machine
Table of Contents

Advertisement

Diagnostics Mode

Press and hold the 'Keylock' and 'Washtemp' buttons. Keeping them pressed for at least 3 seconds, after
which time two beeps will sound and d 00 is displayed.
Note: Diagnostics mode can be entered while the product is running.
While in Diagnostics mode the following components can be operated.
COMPONENT
Hot valve
Cold valve
*Detergent valve
*Fabric softener valve
*Wash boost valve
Hot bowl flag
Pump drain
Recirc valve
Recycle (on/off)
Restart (on/off)
Smart tool opto down load
* CleanSmart™ only
8

DIAGNOSTICS

SELECT
Regular cycle
Heavy cycle
Delicate cycle
Wool/ Easy Iron cycle
THEN TOUCH
Temperature button
Spin button
Options button
Temperature button
Spin button
Options button
Temperature button
Spin button
Temperature button
Spin button
Start/ pause button