133. Repetitive Current Trip; 136. Motor Stall; 137. Motor Loss Of A Phase; 160. Bowl Engaged In Agitate - Fisher & Paykel CleanSmart WL8060P1 Service Diagnostic Manual

Top load washing machine
Table of Contents

Advertisement

133. Repetitive Current Trip

The Motor Control Module has detected excess current in the motor or electronic switches.
See fault code 136

136. Motor Stall

The Motor Control Module has been unable to start the motor.
Primary Source: Wiring.
Action:
Measure/check the motor harness, connectors and motor for discontinuity. This can be done by
taking a resistance measurement between phases of the motor harness at the Motor Control
Module end. Nominal resistance should be around 39Ω.
Secondary Source: Motor.
Action:
Check free rotation of the agitator and bowl by rotating by hand. Bearings and seals may be
seized.
Tertiary Source: Motor Control Module.
Action:
If the primary and secondary checks pass inspection, then replace the Motor Control Module.

137. Motor loss of a Phase

The Motor Control Module has detected the loss of one of the phases of the motor. Possible
causes of this fault are: Faulty motor harness, an open circuit winding of motor or faulty motor
controller.
Primary Source: Wiring
Action:
Measure/check the motor harness, connectors and motor for continuity. This can be done by
taking a resistance measurement between phases of the motor harness at the Motor Control
Module end. Nominal resistance should be around 39Ω.
Secondary Source: Motor.
Action:
Remove Stator and measure / check the resistance of each winding which is approximately 19.5Ω.
Tertiary Source: Motor Control Module.
Action:
If the primary and secondary checks pass inspection, then replace the Motor Control Module.

160. Bowl Engaged In Agitate

The bowl has re-engaged itself during agitate.
Primary Source: Mechanical.
Action:
1) Check that the rotating bowl assembly is not jammed to the agitator with any foreign object
that may be caught under the agitator skirt.
2) Check that the clutch teeth are not locked together with dirt, lint, etc.
3) Make sure the bowl is not overloaded with too many clothes.
4) If none of the above appears to be at fault, then check the air bell at the bottom of the inner
bowl for leaks.
Secondary Source: Installation (drain) set up
Action:
Check that the drain hose is fitted into the drain caddy and extends no more than 20 mm from the
end. Check if fitted to a stand pipe that the drain hose is not pushed down to far.
24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents