COOKTOP BURNERS

lifting off
yellow tip
To check that the ignition system operates correctly, light each burner by itself, then all
z
burners in combination.
Check for a well-defined blue flame without any yellow tipping.
z
If any abnormality is evident, check that the burner assembly is located correctly.
z
When installing the burner port ring, align the two locating pins in the bottom side of the
z
port ring with the locating notch and center holes on the top side of the simmer ring, and
make sure these are properly engaged.
Incorrect installation may produce a dangerous flame and result in poor performance.
z
No air shutter adjustment is possible on the cooktop burners. Proper operation is achieved
z
with factory installed settings for the correct gas type.
If proper operation cannot be obtained, contact Customer Care or your nearest
z
Fisher & Paykel Authorized Service Center.
The range must not be used by the customer until proper operation has been achieved.
z
stable blue flame
z
z
z
If a leak is present: tighten joint or unscrew, apply more joint compound, tighten again and
retest connection for leak.

LEAK TESTING

ON
Ensure all oven and burner knobs are set to
After final gas connection is made, turn gas supply on and test all connections in gas
supply piping for gas leaks with a soapy water solution.
In order to avoid property damage or serious personal injury, never use a Iit match or an
open flame to check for leaks.