Initial Start-up and Loading –
Check the cabinet thoroughly for loose nuts
and bolts and electrical connections. In-
spect the refrigeration lines for any visible
damage or chafing.
Replace the electrical box cover.
Start the cabinet and allow to pull down to
operating temperature before loading.
General Upkeep and Cleaning –
1. To insure good sanitation, appearance, and
minimum maintenance, the cabinet should
be cleaned and washed regularly as sue de-
mands. Clean with mile detergent and
warm water. DO NOT USE AN ABRA-
SIVE CLEANER OR STEEL WOOL AS
THEN WILL MAR THE FINISH.
1. Under normal conditions, after the cabinet
is installed and running, very little mainte-
nance should be required. However, the fol-
lowing list of housekeeping practices will
assure trouble-free operation.
a) Check operation of condenser fan motors.
Fan blades must turn freely.
a) Check drain pan and heater to prevent acci-
dental overflow.
a) Make sure doors are closing properly and
that the gaskets seal.
a) Make sure all evaporator fan motors are
running. These can be seen through grill
inside cabinet.
a) Clean the cabinet with a mild detergent.
this will insure good sanitation, and mini-
mize maintenance. Never use an abrasive as
this could mar the finish.
a) A regular program should be set up for the
cleaning of the fin-and-tube condenser.
Normally, this cleaning is required every 3
to 4 months, but the individual store appli-
cation may shorten or lengthen this time pe-
riod. Dust and dirt accumulation can cause
serious efficiency loss.
a) On the BS cases (bottom mounts) access is
gained to the unit area by removing the lou-
vered grille. The unit slides forward to fa-
cilitate cleaning and for service. Care
should be taken when pushing the unit back
in place to insure that the pullout coil does
not become kinked or damaged in some
way.
OPERATION AND MAINTENANCE
Power Switches –
The power switch is located at the elec-
trical box which is behind the top decorative
panel (TS models) or bottom louvered panel
(BS models). The switch will shut off al power
to the case.
Temperature Control –
The electrical temperature control is located in
the electrical box. The temperature control
does not have an 'OFF' position.
Adjustments may be made by turning
the knob on the face of the dial. Turning it
clockwise will give warmer temperatures while
counter-clockwise will give colder tempera-
tures.