Introduction; Inspection Upon Receipt - Proper Location And Clearance; Skid; Leg Installation - Hussmann HGM-1BS Installation And Service Instructions Manual

Self-contained medium temperature glass door merchandiser
Hide thumbs Also See for HGM-1BS:
Table of Contents

Advertisement

Introduction –
The HGM-BS/TS models are self con-
tained, medium temperature, vertical glass
door merchandisers designed for the display
of dairy products, deli items, beverages, and
wine. Design features include self-closing
glass doors, efficient foamed in place non-
CFC insulation, and balanced R-134a refrig-
eration systems for energy saving perform-
ance.
Inspection upon receipt –
Upon receipt of the cabinet, carefully
examine the crating for damage. If crate is
damaged, make a note on the delivery ticket
before signing. Carefully remove shipping
crate and examine cabinet for "concealed"
damage. If damage is found, contact the de-
livery carrier immediately and have his agent
prepare an inspection report for the purpose
of filing a claim. THIS IS YOUR RESPONSI-
BILITY.
Proper Location & Clearance –
Avoid locating the cabinet where direct
sunlight would shine into the fixture or where
drafts from air conditioning grills, fans and
open doors could affect its operation.
Because the condensing unit is located
at the top of the HGM-TS, at least twelve (12)
inches of clearance should be allowed at the
rear of the cabinet and at the top of the case.
This clearance is necessary to provide free air
movement to and from the condenser for
maximum operating efficiency.
Because the condensing unit is located
on the bottom of the HGM-BS, at least twenty
four (24) inches of clearance should be
allowed in front of the case and six (6) inches of
clearance at the rear to provide the necessary
free air movement to and from the condenser.
INITIAL SET-UP Skid –
The skid should be left on the case until it
is near its final location. The skid provides pro-
tection for both case and floor. The skid is re-
moved by raising one end of the case approxi-
mately six inches. Block securely and remove
the two skid bolts on the raised end. The proce-
dure is repeated on the opposite end. When the
skid bolts are removed, the case may be slid off
the skid.
Leg Installation – Top Mounts only
After the case is near its final location
and the skid has been removed, the NSF ap-
proved legs should b e installed. The legs are
packaged inside the cabinet. Replace the tape
and door blocks. To install legs, raise one end of
the cabinet approximately eight (8) inches, block
securely, and install two legs.
The leg mounting plates are factory in-
stalled and contain a ½ x 13 tapped hole to mate
with the leg assembly. The procedure is re-
peated on the opposite end. The 3-door requires
legs in the center. With cabinet legs installed,
the cabinet should be positioned in its final loca-
tion and leveled.
The cabinet is leveled by turning the bottom sec-
tion of each leg. The self-closing doors require
the cabinet to be properly leveled. End to end
leveling will make the door (s) close with uni-
form speed and tightness. A slight pitch from
front to rear is desirable.
Page 2