Condensate Pan; Bottom Louvered Panel Removal; Top Decorative Panel Removal; Compressor - Hussmann HGL-1BS Installation And Service Instructions Manual

Bottom / top mount self-contained merchandisers
Hide thumbs Also See for HGL-1BS:
Table of Contents

Advertisement

leveled. End to end leveling will make the door (s)
close with uniform speed and tightness. A slight
pitch from front to rear is desirable. THE CABI-
NET BACK SHOULD NEVER BE HIGHER
THAN THE FRONT.
Leveling & Sealing – Bottom Mounts Only
The case can be leveled by shimming under
the cabinet base frame, or by installing optional
levelers. The self-closing doors require the cabinet
to be properly leveled. End to end leveling will
make the doors close
with uniform speed and tightness. A slight pitch
from front to rear is desirable. Once level the case
should be sealed to the floor as shown in the fol-
lowing drawing, using an NSF approved material
such as General Electric RTV-102 silicone sealer
or an equivalent.
S ilic o n e S e a la n t
F lo o r
Conensate Pan –
An electrically heated (300W, 208-230v)
condensate pan is provided to evaporate the de-
frost water. The heated condensate pan slides
onto the slide plate on the cabinet bottom on both
the TS and BS cases. The pan is removable for
cleaning. A vinyl drain tube is provided for con-
nection to the heated condensate pan. The drain
must be trapped to guard against drain line freez-
ing and for good sanitation practice.
Bottom Louvered Panel Removal –
The louvered panel provides access to the
condensing unit and the electrical box. Remove
panel by removing shipping screw (s) at
bottom and lifting up and pulling forward. Re-
move shipping screw on electrical box to allow the
electrical box to slide out for servicing.
Top Decorative Panel Removal –
The top decorative panel is removed by lift-
ing up and pulling forward.
Compressor –
The compressor is mounted on springs and
banded for shipping purposes and this band needs
to be cut upon installation. Do not loosen the com-
pressor mounting bolts, as these are factory pre-set
for proper riding on the springs.
Shelves –
Each cabinet is provided with 4-cantilever
shelves per door that are adjustable on 1-inch in-
crements and are tiltable. Each cabinet also has
one bottom shelf per door. These shelves have one
inch legs to allow proper airflow in the cabinet.
Behind the shelves are wire flue spacers which also
allow for proper airflow. All shelves and flue spac-
ers are white, epoxy coated for durability and ease
of cleaning. Shelves should be adjusted to desired
operating height.
When loading product into the cabinet, care
should be taken not to load product so that it
touches the evaporator coil cover, also, do not ex-
tend product past the front edge of the shelf. Ex-
tending past the edge will seriously effect internal
air flow through out the cabinet.
Shelves are UL rated for a maximum load of
123 lbs. DO NOT OVERLOAD SHELVES.