It is important to use an accurate periodically calibrated high
voltage meter.
3. Measure the High Voltage. The meter (electrostatic type) reading
should indicate 2.2 kV±0.1 kV. If the meter indication is out of
tolerance, immediate service and correction is required to prevent
the possibility of premature componentfailure. To prevent an X-
Radiation possibility, it is essential to use the specified picture
tube.
4. OPERATION GUIDE
5. SERVICE NOTES (PLEASE READ)
5.1. SERVICE NOTES
5.1.1. EXTENSION CABLES FOR SERVICE POSITION
Using the following Extension Cables, place the unit as shown for check and service.
Extension Cables (No.5 ~ No.8) are used for improving serviceability. (They are not necessarily
used.)
Note :
1. The LCD open/close SW. is for changing between LCD Display or
EVF Display. When turning on LCD Display, place some paper or
tape, etc. on LCD open/close SW. so that this SW. stays ON.
2. (For early products)
Be sure to attach the Short JIG C.B.A. on Connector B3. Refer to "
SHORT JIG
C.B.A."
3. Use a grounded ESD wrist strap while disassembling the Lens
portion.
4. Use extreme care when unplugging or plugging in connectors.
Fig. 1-1
6