Set Up; Electrical Connection - Hoshizaki KM-500MAH Instruction Manual

Modular crescent cuber
Hide thumbs Also See for KM-500MAH:
Table of Contents

Advertisement

4. SET UP

1) Unpack the Storage Bin, and attach the four adjustable legs
provided (bin accessory) to the bottom of the Storage Bin.
2) Position the Storage Bin in the selected permanent position.
3) Place the icemaker on the top of the Storage Bin.
4) Secure the icemaker to the Storage Bin, by using the
two mounting bracket and the four bolts provided.
See Fig. 2
5) Level the icemaker/Storage Bin in both the
left-to-right and front-to-rear directions.
Adjust the Ice Bin Legs to make the icemaker level.
6) Replace the panels in their correct positions.

5. ELECTRICAL CONNECTION

1. Electrical connection must be made in accordance with the instructions on
a "WARNING" tag, provided with the pigtail leads in the Junction Box.
2. This icemaker requires a ground that meets the national and local electrical
code requirements. To prevent possible electrical shock to individuals or
extensive damage to the equipment, install a proper ground wire to the
icemaker.
• The white lead must be connected to the neutral
conductor of the power source. Miswiring results in
severe damage to the icemaker. See Fig. 3.
• This icemaker must have a separate power supply or
receptacle of proper capacity. See the Nameplate.
• The opening for the power supply connection is
7/8" diameter to fit a 1/2" trade size conduit.
• Usually an electrical permit and services of a licensed
electrician are required.
WARNING
12
Icemaker
Bolts
Bin
Mounting
Brackets
Fig. 2
Fig. 3

Hide quick links: