1. CHECKS BEFORE INSTALLATION

Remove shipping carton, tape(s) and packing. If packing material is left in the
icemaker, it will not work properly.
1) Remove the panels to prevent damage when installing the icemaker. See "2. HOW TO
REMOVE PANELS."
2) Remove the package containing the accessories.
3) Release the Bin Switch assembly:
a) Remove the Base Cover to access the Bin Switch assembly.
b) Remove the Bin Control Shield by loosening the thumbscrew.
c) Remove the shipping tape holding the switch actuator arm and paddle in
place so that the paddle swings down freely.
d) Replace the Shield, secure the thumbscrew and replace the Base Cover.
4) Remove the protective plastic film from the panels. If the icemaker is exposed to the sun
or to heat, remove the film after the icemaker cools.
5) Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the
fan blade turns freely.
6) Check that the Compressor is snug on all mounting pads.
7) See the Nameplate on the Rear Panel, and check that your voltage supplied corresponds
with the voltage specified on the Nameplate.
8) This icemaker needs a storage bin. The recommended storage bin is HOSHIZAKI ICE
STORAGE BIN, Model B-300 series.
9) On remote air-cooled models, a remote condenser unit is needed. The recommended
remote condenser unit is HOSHIZAKI CONDENSER UNIT, MODEL URC-6F.