Hoshizaki KM-500MAH Instruction Manual page 25

Modular crescent cuber
Hide thumbs Also See for KM-500MAH:
Table of Contents

Advertisement

Note: To remove cubes on the Evaporator, turn off the power supply and turn it on after
3 minutes. The defrost cycle starts and the cubes will be removed from the
Evaporator.
3) Turn off the power supply.
4) Remove the Front Panel and the Base Cover, and then remove the Insulation Panel by
lifting up the panel slightly and pulling it toward you.
5) Remove one end of the Pump Tubing. Drain the Water Tank. Replace the Pump Tubing
in its correct position. See Fig. 11.
6) Pour the cleaning solution into the Water Tank.
7) Fully open the Cleaning Valve on the left side wall of the machine compartment.
8) Move the Control Switch, on the Control Box, to the "WASH" position
9) Replace the Insulation Panel and the Front Panel in their correct positions.
10) Turn on the power supply, and start the washing process.
11) Turn off the power supply after 30 minutes.
12) Remove the Front Panel.
13) Remove one end of the Pump Tubing. Drain the Water Tank. Replace the Pump Tubing
in its correct position.
14) Move the Control Switch to the "ICE" position.
15) Close the Cleaning Valve.
16) Replace the Front Panel in its correct position.
17) Turn on the power supply to fill the Water Tank with water.
18) Turn off the power supply after 3 minutes.
19) Remove the Front Panel, and fully open the Cleaning Valve.
20) Move the Control Switch to the "WASH" position.
21) Replace the Front Panel in its correct position.
22) Turn on the power supply to rinse off the cleaning solution.
23) Turn off the power supply after 5 minutes.
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-500mrhKm-500mwfKm-500mwh

Table of Contents