Minimum Wall and Ceiling Clearances
This fireplace can be installed with zero clearance to
combustible material.
When facing the front of the appliance the minimum clearances to
combustible construction (material) are the following:
1.
Clearances from the right side or left side of the fireplace opening
to any combustible wall or material should not be less than 4
inches.
2.
Clearances from the top of the fireplace opening to the ceiling
should not be less than 34-3/16 inches.
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
Page 6
CLEARANCES
34 3/16"
(843mm)
Figure 4
COMBUSTIBLE MATERIAL
Figure 6
Mantel Clearances for Built-in Installation
15 3/16"
(386mm)
14 7/16"
(367mm)
13 11/16"
(348mm)
12 15/16"
(329mm)
9 11/16"
(246mm)
Top of Opening
No greeting cards, stockings or ornamentation of any type should be
placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
Mantel
12"
(305mm)
10"
(254mm)
8"
(203mm)
6"
(152mm)
4"
(102mm)
2 1/2"
(63mm)
8 15/16"
(227mm)
Figure 5
30411-17-0120