11) Debug Function Setting
Debug Function(Setting of Ambient Temp. Sensor)
When the unit is shut off, press the "FAN" key and the "SLEEP" key
simultaneously to activate the debug menu. Now the LCD displays
"DEBUG". Press the "MODE" key to select setting item and use the
" " key or the " " key to set actual valve.
Setting of Ambient Temp. Sensor
Under the debug mode, press the "MODE" key so as to display "01" on
the set temperature area (at the left of "DEBUG"). The OUT ENV area
(at the right of "DEBUG") displays setting status. Now use the " " key
or the " " key to select from the following two settings:
SWING
①The indoor room temperature is measured at the air intake (Now the
OUT ENV area displays 01).
②The indoor room temperature is measured at the wire controller
( Now the OUT ENV area displays 02).
The default room temp. sensor is located at the air intake.
The indoor room temperature is measured at the wire controller
when the mode is 'heating' or 'auto'. At other modes,it is measured at
the air intake(Now the OUT ENV area displaus 03) ,The default is 03.