memorize startup and stop status of the unit or not at unit.01
displayed in the region of displaying setting temp indicates
memorizing start and stop status of the unit after power
off .02, quit by pressing ON/OFF button ,indicates not
memorizing. If after the interface of memorizing startup and
stop status of the unit appears, there is no operation in 20s
when the system responds the last press of one button, the
system will trip off the menu and display normal stop interface,
but it also memorizes present information.
10)Malfunction Display (Fig.19)
If malfunction happens during operating of the unit, ERROR will
blink with error code displayed. For example, the right figure
indicates compressor low-pressure protection.
Codes
Malfunction
E0
Water pump malfunction
E1
Compressor high-pressure protection
E2
Indoor anti-freezing protection
E3
Compressor low-pressure protection
E4
Compressor high-temp. exhaust protection
E5
Compressor overload protection
E6
Communication malfunction
E8
Indoor fan protection
E9
Water-full protection
F0
Air inlet indoor ambient temp. sensor malfunction
F1
Evaporator temp. sensor malfunction
F2
Condenser temp. sensor malfunction
F3
Outdoor ambient temp. sensor malfunction
F4
Exhaust ambient temp. sensor malfunction
F5
Ambient temp. sensor malfunction in displayer