Devices
1.6.4 Relay Modules
These addressable modules provides the control panel with a dry-contact output for activating a variety of auxiliary devices.
FRM-1 Relay Module with two Form-C relays; FlashScan or CLIP mode.
XP6-R Controls six independent Form-C relays; FlashScan or CLIP mode.
1.6.5 Multiple Input/Output Modules
These addressable modules offer dual input and/or dual ouput in a single device.
FDM-1 Dual Class B Monitor Module; FlashScan or CLIP mode.
FDRM-1 Dual Monitor/Dual Relay Module; functions as two Class B monitor modules and two individual relay modules.
FlashScan or CLIP mode.
1.6.6 Transponders
XP Series (XPP-1, XPC-8, XPM-8 & XPR-8) Provides the FACP with an efficient multiplex subsystem capability. It
communicates with the FACP and functions as a data-gathering panel for alarm Initiating Device Circuits and as a remote switching
center for Notification Appliance Circuits (NAC), telephone circuits or relays. Not FlashScan capable.
For information on connecting these transponders to the SLC, refer to the XP Transponder Manual.
1.6.7 Plug-in Detector Bases
Plug-in detector bases provide a connection between the SLC and a variety of intelligent detectors which are snapped into place. Stan-
dard and isolator bases are used depending upon which NFPA SLC style is required. Sounder and relay bases are similar to standard
bases, but have sound or relay capabilities.
Standard Base
– B501 . 4 inch (10.16 cm) standard small diameter base, commonly used in European installations. ) White. For ivory, order
B501-IV. For black, order B501-BL.
Note: UL/ULC listed as of January 2018 to replace B501A; compatible for use in Canadian retrofit installations.
– B300-6 6 inch (15.24 cm) plug-in detector base standard large diameter base, commonly used in US installations.
White. For ivory, order B300-6-IV. Replacement model for B210LP.
– B210LP 6 inch (15.24 cm) standard large diameter base, commonly used in US installations, replacement model for B710LP).
HARSH™ Base - Model B710HDused with all HARSH™ detectors
Isolator Base B224BI, B224BI-IV isolator base.
Sounder Base
– B501BH Standard sounder base.
– B501BH-2 UL 864 9th edition compliant standard sounder base.
– B501BHT-2 UL 864 9th edition compliant temporal sounder base, replaces B501BHT.
– B200S. Intelligent sounder base.
– B200SR Intelligent sounder base, designed to be compatible with existing installations of the B501-Series sounder bases.
– B200S-LF A low-frequency version of the B200S
– B200SR-LF A low-frequency version of the B200SR.
Relay Base B224RB, B224RB-IV
1.6.8 Intelligent Detectors
FCO-851 IntelliQuad PLUS Intelligent Photoelectric Multi-Criteria Smoke/CO (Carbon Monoxide) detector. Plug-in type smoke sensor
that is a photoelectric sensing chamber combined with Carbon Monoxide (CO), thermal, and infra-red (IR) sensors to help reduce false
alarms. For CO, the detectors electromechanical sensing cell creates a separate indication of for life safety CO detection. The FCO-851
adds thermal sensors that will alarm at a fixed temperature of 135° F (57.2° C) and alarm sensitivity options with built-in alarm and pre-
alarm time delay. FlashScan mode only.
FSB-200S Addressable, intelligent, single-ended beam smoke detector with built-in sensitivity testing. The FSB-200 is the same except
that it does not provide sensitivity testing. Both models support FlashScan and CLIP mode.
FAPT-851 (Acclimate
heat detection (135°F / 57.2°C). FlashScan- and CLIP-mode capable. (An earlier version named FAPT-751 was also FlashScan capable.
The model named IPX-751 was discontinued as of December 1, 2001.)
FSC-851 IntelliQuad Intelligent Photoelectric Multi-Criteria Smoke Sensor. Plug-in type smoke sensor that is a photoelectric sensing
chamber combined with Carbon Monoxide (CO), thermal, and infra-red (IR) sensors to help reduce false alarms. The FSC-851 adds
thermal sensors that will alarm at a fixed temperature of 135° F (57.2° C) and alarm sensitivity options with built-in alarm and pre-alarm
time delay. Notifier panels offer different feature sets across different models. Certain features of the FSC-851 may not be available on
some panels. The FSC-851 supports both FlashScan and CLIP modes. Read Status limitations may apply in CLIP mode.
FSI-851 Addressable, intelligent smoke detector that incorporates an ionization sensing chamber. Designed to provide open area protec-
tion. FlashScan- and CLIP-mode capable. (An earlier model named FSI-751 (discontinued) was also FlashScan- and CLIP-mode capa-
ble. Earlier models named CPX-751 and CPX-551 were CLIP mode only.)
FSP-951/FSP-951-IV Analog, addressable intelligent smoke detector that uses a photoelectric sensing chamber. Listed for use in ducts.
Designed to provide open area protection. The FSP-951T/FSP-951T-IV adds thermal sensors that will alarm at a fixed temperature of
135° F (57.2°C). The FSP-951R/FSP-951R-IV is a low profile, intelligent photoelectric sensor that is remote test capable, for use with
DNR(W). Basic models support FlashScan mode only; models ending in -IV support FlashScan and CLIP mode. These models update
Notifier SLC Wiring Manual — P/N 51253:U5 12/20/2017
®
Plus™) Addressable, intelligent detector that combines a photoelectric sensing chamber and fixed temperature