Honeywell Notifier AFP-100 Wiring Manual page 74

Intelligent control panel slc
Table of Contents

Advertisement

Canadian Versions of SLC Devices
UL-listed SLC Device
FSA-5000
FSA-8000
FSA-20000
FSA-20000P
Bases
B300-6
B300-6-IV
B210LP
B501
B501-IV
B501-BL
B710LP
B501BH, B501BHT
B501BH-2, B501BHT-2
B224RB
B224BI
B710HD
B200S
B200SR
Note: Because the low-frequency bases are designed for a UL requirement,there is no ULC-listed version of B200S-LF/B200SR-LF
Monitor and Zone Interface Modules
FMM-1
FZM-1
FDM-1
FMM-101
Pull Stations
NBG-12LX
N/A
Control Modules
FCM-1
FCM-1-REL
FRM-1
74
ULC-listed SLC Device
FSA-5000A
FSA-8000A
FSA-20000A
FSA-20000P
B3006A
B3006A-IV
B210LPA
B501 (Manufactured 1/2018
or later); B501A
(manufactured before 2018)
B501-IV
B501-BL
B710LPA
B501BHA, B501BHTA
N/A
B224RBA
B224BIA
B710HDA
B200SA, B200SCOA
B200SRA
FMM-1A
FZM-1A
FDM-1A
FMM-101A
NBG-12LX
N-MPS Series
FCM-1A
FCM-1-RELA
FRM-1A
Intelligent FAAST XS aspiration smoke detector, covers up to 5,000 square
feet. FlashScan mode.
Intelligent FAAST XM aspiration smoke detector, covers up to 8000 square
feet. Supports FlashScan and CLIP mode. (An earlier model was CLIP mode
only).
Intelligent FAAST XT aspiration smoke detector, covers up to 28,800 square
feet. FlashScan mode.
Intelligent FAAST XT PRO aspiration smoke detector, covers up to 28,800
square feet through addressable pipes. FlashScan mode UL-/ULC-listed
model.
Standard U.S. Low-Profile base (6", 15.24 cm). White.
Standard U.S. Low-Profile base (6", 15.24 cm). Ivory.
Standard U.S. Low-Profile base (6", 15.24 cm).
Standard European flangeless base (4", 10.16 cm). White.
Ivory version of B501.
Black version of B501.
Standard U.S. Low-Profile base (6", 15.24 cm). Discontinued.
Sounder base, includes B501/A Sounder base with temporal sounder (UL
8th Edition) Discontinued.
Sounder base, includes B501/A Sounder base with temporal sounder (UL
9th Edition) Discontinued.
Low Profile Intelligent relay base.
Low Profile Intelligent isolator base.
Base for a hostile environment detector.
Addressable sounder base.
CO detector markings in English/French, for
B200SCOA provides
Canadian applications only.
Sounder base.
Used for normally open contact alarm initiating devices, such as manual pull
stations, four-wire smoke detectors, heat detectors, waterflow, and
supervisory devices.
Used to interface with two-wire smoke detectors in addition to normally open
contacts.
Provides two independent 2-wire Initiating Device Circuits (IDCs) at two
separate, consecutive addresses. Wire supervised IDCs as NFPA Style B
(Class B) or Style D (Class A) circuits. The modules come with a
thermoplastic cover for mounting to a 4-inch (10.16 cm) square mounting
box.
Functionally similar to the FMM-1 Monitor Module, but offered in a smaller
package for mounting directly in the electrical box of the device being
monitored. (Class B input circuit only.)
An addressable manual pull station with key-lock reset feature. The
addressable module is housed within the pull station.
Addressable manual pull stations with hex key reset feature. The
addressable module is housed within the pull station.
Control Module, NAC: Addressable Control Module used as Notification
Appliance Circuits (NACs) to power and supervise compatible, UL-listed
notification appliances. Wired supervised NACs as NFPA Style Y (Class B)
or Style Z (Class A). The modules come with a thermoplastic cover for
mounting to a 4-inch (10.16 cm) square mounting box.
Control Module for releasing applications. FlashScan only.
Relay Control Module is similar to the FCM-1 except used as a Form-C
control relay module.