System Options (Continued)

Keypad Lockout Count
The system counts the number of invalid Entry Codes entered at the
keypad. If the invalid entries exceeds the lockout count number, the
keypad is locked out for 90 seconds. The factory setting for the lockout
count is three. The lockout value can be from one to nine.
1. Press
2. Enter the number for the lockout count (1-9).
3. Press
Access Relay Activation Time
The factory setting will cause the access relay to activate for 4 seconds.
The activation time can be set from 4-99 seconds to accommodate
different types of access control devices.
1. Press
2. Enter the time (in seconds) for access relay to stay activated (04-99)
3. Press
Welcome Display Text
The AE-100 display will show a visitor a welcome message alternating
with instructions on how to fi nd and call a resident. The welcome message
can be customized to suit the installation.
✦ NOTE: This step cannot be performed remotely through the telephone.
1. Press
✦ NOTE: To enter capital letters only, press
2. Enter the new text for the top line of the display (up to 16 characters).
3. Press
✦ NOTE: To enter capital letters only, press
4. Enter the new text for the bottom line of the display (up to 16 characters).
5. Press
Automatic Telephone Answer
The factory setting will allow the system to detect a ring signal on the
telephone line and answer the call.
✦ NOTE: The automatic answer feature can be turned off, although remote
programming, remote access control by residents, and resident call-back
features will no longer function.
1. Press
2. Select the option for automatic telephone answering:
Enter 0 to turn OFF automatic telephone answering.
Enter 1 to turn ON automatic telephone answering.
3. Press
Speaker Chirp on Keystrokes
The factory setting will cause the speaker to chirp when each key on the
keypad is pressed. Alternately, the speaker chirp can be turned off.
1. Press
2. Select the option for keystroke speaker chirps:
Enter 0 to turn OFF the keystroke speaker chirps.
Enter 1 to turn ON the keystroke speaker chirps.
3. Press
STANDARD PROGRAMMING METHOD
fi rst before entering the text.
fi rst before entering the text.
KEYPAD LOCKOUT COUNT
51#COUNT#
COUNT = NUMBER (1-9) OF INCORRECT ENTRIES
THAT WILL CAUSE A 90 SECOND LOCKOUT
FACTORY SETTING: 3 TRIES
ACCESS RELAY ACTIVATION TIME
52#SECONDS#
SECONDS = ACTIVATION TIME (04-99 SECONDS)
FACTORY SETTING: 4 SECONDS
WELCOME DISPLAY TEXT
57#LINE 1#LINE 2#
LINE 1 = UP TO 16 CHARACTERS TEXT
LINE 2 = UP TO 16 CHARACTERS TEXT
FACTORY SETTING: LINEAR ACCESS TELEPHONE ENTRY
AUTOMATIC TELEPHONE ANSWER
61#ANSWER#
ANSWER = 0 FOR AUTO ANSWER OFF
ANSWER = 1 FOR AUTO ANSWER ON
FACTORY SETTING: AUTO ANSWER ON
SPEAKER CHIRP ON KEYSTROKE
62#CHIRP#
CHIRP = 0 FOR KEYSTROKE CHIRP OFF
CHIRP = 1 FOR KEYSTROKE CHIRP ON
FACTORY SETTING: KEYSTROKE CHIRP ON
PPN 51
PPN 52
PPN 57
PPN 61
PPN 62