Step 5: Wire the Speaker

Connect the wires to the speaker using the detachable 4 pole phoenix connector as
illustrated in Figure 10. The 4 connections allow for convenient loop through wiring to
the next speaker system wired in the system.

Step 6: Secure the Seismic Tab Connection Point

The rear of the enclosure includes an eyebolt for connection to a seismic restraint.
Connect it to a properly rated hardware fitting that is securely installed independently of
the SAM™ bracket. Maintain a 12" (305mm) maximum length of slack or less. Even if
your local construction code does not require the installation of secondary support, its
use is highly recommended as additional security.
Phoenix
Connector
Polarity Detail
Figure 10: Wiring and Seismic Tab Connections

Step 7: Test System Operation

After all connections are made, test the complete system operation. Appendix A (page
10) contains a troubleshooting table to assist in locating many speaker-related
problems.

Maintenance

Your Zx1™ system has been designed and manufactured to provide years of durability
and reliable service. No routine maintenance is necessary. Units may be cleaned by
wiping with a soft, damp cloth. Never use solvents or harsh cleaning agents of any kind.
®