Remote Control Connections; Led's - Leviton 2408CD Installation & Operation Manual

Commercial dimmer pack
Table of Contents

Advertisement

For house lighting and architectural systems
Make sure the jumper block on each control card is installed across
both jumper pins marked SPCL on the. It is also a good idea to make
sure the jumper is installed across both jumper pins marked
SOFTSTART (CD's only).
For Stage Lighting Systems
Make sure the jumper block on each control card is NOT across both
jumper pins marked SPCL. You must also remove the SOFTSTART
jumper on each control card so the lights will not appear sluggish in
response.
NON-DIM CHANNELS
Any of the channels of the 2408 CD can be configured as NON-DIM
channels. This will cause the output of the channel to go to full on
whenever the input signal is over 10. When to input signal drops
to less than 100C; the channel output goes to full off. This is the
equivalent of a zero-crossing solid state relay.
To configure a channel for NON DIM operation simply remove the
jumper block from the pins on the firing card as indicated. Replacing
the jumper block will restore dimming operation.
CHANNEL
JUMPER BLOCK
1
J8
2
J9
3
J10
4
J11
5
J8
6
J39
7
J10
8
J11
Installation & Operation Guide
Page 13
FIRING CARD
1-4
1-4
1-4
1-4
5-8
5-8
5-8
5-8
FIRING CARD
DIP SWITCH
8-18 VOLT INPUTS
POWER SUPPLY I/O CARD
COMMON
DMX -
DMX +
MCPX
Figure 4
CONTROL WIRING

Remote control connections

Special accessories manufactured by Leviton may be connected to
this dimmer, such as the 400CP control panel for doorways. See the
installation instructions that come with these accessories.

LED'S

The indicator LED's on the dimmer firing cards indicate the status of
the dimmer.
• RED: Indicates the card is receiving DC power (both cards will
light even if only one line is energized).
• GREEN: Steady indicates a multiplex control signal is being
received. Flashing indicates that a fade, initiated from a remote
panel, is in process.
• YELLOW: Indicates a respective dimmer channel is active and
LED indicates relative intensity.
Installation & Operation Guide
PWR
1 2 3 4
MPX
COMMON
+15V
REM +
REM -
Page 10