________________________________________________________________

Control Wiring

DMX-512:
Input = 5 pin XLR-M
Through Output = 5 pin XLR-F
Recommended
Control Wire:
Belden 9729 or 9829
Microplex:
Input = 3 pin XLR-M
(MPX)
Through Output = 3 pin XLR-F
Recommended
Control Wire:
Belden 8760 or 9460
0-10VDC:
Input = 15 pin M D-Sub
Analog
Recommended
Control Wire:
Alpha 1896
Luma-Net
Input = 6 pin pluggable terminal block
Orientation: looking at back of pack,
with grooved surface on bottom.
Recommended
Control Wire:
Alpha 1898
IMPORTANT NOTE: Do not route low voltage control wires parallel to or in the same conduit as high voltage
power wires as the control system may exhibit erratic control performance. (like flickering)
NSI DS8/DS12 MODULAR DIGITAL DIMMING SYSTEM
Software Revision 1.1x, 8/24/99
- 5 -
Pin#
Signal
1
DGND
2
DATA -
3
DATA +
4
THROUGH
5
THROUGH
Pin#
Signal
1
Analog COM
2
+14.4VDC Power
3
DATA
Pin#
Signal
1
Channel 1
2
Channel 2
3
Channel 3
4
Channel 4
5
Channel 5
6
Channel 6
7
Channel 7
8
Channel 8
9
Channel 9
10
Channel 10
11
Channel 11
12
Channel 12
13
T/C (Snapshot)
14
+14.4VDC Power
15
Analog COM
Pin#
Signal
1 (far right)
REM +
2
REM -
3
DGND
4
+14.4VDC Power
5
N/C
6 (far left)
N/C