Carefully plan position of roof penetration. This appliance is only compatible with a vertical flue.
Heater MUST BE positioned so that vertical flue path avoids roof structure. Additional flue
IMPORTANT
bends to avoid roof structure and other obstructions MUST NOT be used.

FLUE INSTALLATION

1.
Prepare roof penetration at 125mm Ø to suit B065412 650FS-ROOFCOWL and ceiling penetration to suit
1399901 Single Swage Tube.
2.
Fit one section of 13901013 PVC Tube to the large ring on the flue adapter A. Flare end up.
3.
Fit B065413 Double Swaged Aluminium Tube and B065456 white split locator to the small ring on the flue
adapter ensuring the spacer B is correctly located at the top end of the assembly. Use the supplied silicone
grease to lubricate all red 'O' rings and cup seals C.
Use only a silicone based 'O' ring seal lubricant. DO NOT use petroleum based lubricants such
as petroleum jelly as these products may cause deterioration.
IMPORTANT
Two containers of silicone grease are provided. To ease assembly, lubricate the 'O' rings and
cup seals of each flue component prior to assembly.
Rinnai
B
A
15
FLUE INSTALLATION
C
C
650FS FIM