INSTALLATION - SOLAR COLLECTORS

REGULATIONS AND OCCUPATION HEALTH AND SAFETY (OH&S)
Installation and commissioning must be performed by authorised persons. Rinnai solar systems must be installed
in accordance with these Instructions and all regulatory requirements which exist in your area including those in
relation to manual lifting, working at heights and on roofs. Applicable publications and regulations may include:
AS/NZS 5601 Gas Installations
AS/NZS 3500 National Plumbing and Drainage
AS/NZS 3000 Wiring rules
Building Codes of Australia
Local Occupational Health and Safety (OH&S) regulations
Solar collectors are heavy and bulky items and are usually positioned on the roofs of buildings.
Each Australian State and Territory has a principal Occupational Health and Safety (OH&S) Act
which contains requirements relating to the handling of large, bulky or awkward items and the
WARNING
prevention of falls from elevated surfaces. Persons installing solar collectors must be aware of
their responsibilities and be adequately trained and qualified, in accordance with local OH&S
requirements.

SOLAR COLLECTOR SPECIFICATIONS

Model
Type
Waterways
Absorber
Selective Surface
Maximum Operating Pressure
Casing Material
Overall Dimensions
(L x W x H) (mm)
Weight empty (kg).
Water volume (litres)
Number risers
Potential Solar Output at
PTR relief conditions (kW)
Frost Protection
Rinnai
The Rinnai solar hot water warranty booklet specifies the locations and
conditions that apply for flat plate collectors to be warranted against frost
For full warranty terms, conditions and exclusions refer to the Rinnai solar
hot water warranty booklet. The booklet is available at www.rinnai.com.au.
12
ENDURO
SP200B
Flat plate
Copper
Aluminium
High Performance
1000 kPa
Aluminium
1960 x 1050 x 80
40
1.95
9
1.25 kW
damage.