THIS MANUAL MUST BE READ IN ITS
ENTIRETY BEFORE OPERATING HEATER
Owners Operation and Installation Manual
WARNING: If the information in these instructions are not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
This heater has been designed to code ANSI Z 21.88a-2000
effective 7-1-2002
This appliance is only for use with the type of gas indicated on
the rating plate.
This appliance is not convertible for use with other gases.
INSTALLER: MUST LEAVE THIS MANUAL WITH THE UNIT AFTER INSTALLATION
OWNER: RETAIN THIS MANUAL SAFELY, FOR FUTURE REFERENCE
HOME OWNER / INSTALLER
FOR YOUR SAFETY
IB35RBN/US
IB35RBL/US
Gas Radiant Space Heater
WHAT TO DO IF YOU SMELL GAS

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai IB35RBN

  • Page 1 HOME OWNER / INSTALLER FOR YOUR SAFETY THIS MANUAL MUST BE READ IN ITS ENTIRETY BEFORE OPERATING HEATER IB35RBN/US IB35RBL/US Gas Radiant Space Heater Owners Operation and Installation Manual WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Limited Warranty

    Authorized Rinnai Distributor. Rinnai will not pay labor charges associated with the repair or replacement of the product or any part or component. All repair parts must be genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that has been authorized by Rinnai or its distributor.
  • Page 3: Table Of Contents

    MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. This manual applies to the following models only: IB35RBN/US IB35RBL/US Inbuilt Fire Table of Contents Limited warranty ......................2 Contacts ........................
  • Page 4: Specifications

    SPECIFICATIONS Model: IB35RBN/US (NG) United States IB35RBL/US (Propane) United States Description: Inbuilt radiant/convector, glass-fronted, ceramic log space heater with fan forced convection and natural draft flue system Output: 26,000 Btu/hr Natural Gas 23,000 Btu/hr Propane Gas Control: Push button combination control valve...
  • Page 5: Important Points / Usage And Installation Musts

    IMPORTANT POINTS / USAGE AND INSTALLATION MUSTS Unpack the heater and check for damage (DO NOT INSTALL DAMAGED HEATER). If the heater is damaged, contact your supplier for advice. Before installing the heater, check the label for the correct gas type (see rating plate, bottom right hand side of pillar). Refer to local gas authority for confirmation of the gas type if you are in doubt.
  • Page 6 15 Do not use this appliance if any part has been under water. Immediately call a The appliance must be isolated from the qualified service technician to inspect gas supply piping system by closing its the room heater and to replace any part equipment shutoff valve during any of the control system and any gas control pressure testing of the gas supply piping...
  • Page 7: Technical Specifications

    34 The glass window shall be replaced as 33 INSTALLATION AND REPAIR SHOULD one piece as supplied by the BE DONE BY A QUALIFIED SERVICE manufacturer. See glass and log PERSON. THE APPLIANCE SHOULD installation on page 14 BE INSPECTED BEFORE USE AND LEAST ANNUALLY 35 Do not substitute glass, glowing embers...
  • Page 8: For Your Safety Read Before Operating Heater

    FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A This appliance is equipped with an a neighbour’s phone. Follow the gas ignition device which automatically suppliers instructions.
  • Page 9: Operation

    OPERATION The controls on your new Flame Fire are situated on the lower front right hand side. All necessary adjustments to the operation of your fire can be made with these controls. • TO TURN ON THE PILOT Press the right hand control button firmly. •...
  • Page 10: Location

    LOCATION When positioning the heater, the main points governing the location are: 1. Flue connection and proper venting 10. Before installing the heater, inspect the chimney, flue piping and/or solid fuel 2. Warm air distribution. burning fire place and remove any combustible materials.
  • Page 11 • Fireplace dimensions There are two types of installation that may be used with this heater. • Non-combustible (masonry, brick etc.) fire place. • Zero clearance kit installation, for installation in combustible materials. In each case there are minimum and maximum dimension that the fire place or opening must fall within, as shown in these diagrams.
  • Page 12: Venting

    VENTING Use only an approved B vent system. An approved chimney liner must be used. It is recommended that the flue be installed vertically only. If installation prevents this then there must be at X/3 maximum least 4 feet of vertical flue before any bends.
  • Page 13: Electrical Connection

    ELECTRICAL CONNECTION There is a junction box provided at the front of the heater for the electrical connection. WARNING: This appliance must be properly grounded for your protection against shock hazard. Connecting the power supply: Refer to the diagram opposite, 1 Open the side doors.
  • Page 14: Log Installation

    LOG INSTALLATION The logset is packed inside the unit and the packaging must be removed prior to installing the logset in its correct position. • Open both side panels. • Remove fasteners on both sides of the top glass retainer. •...
  • Page 15: Testing And Commissioning

    TESTING AND COMMISSIONING TESTING PROCEDURE It is the responsibility of the installer to check that under normal operating Turn gas supply on and plug the unit into conditions of the appliance, all flue gases the power supply. (Caution 115V) are exhausted to the outside atmosphere and that there is no spillage of combustion gases into the room.
  • Page 16: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS IMPORTANT MAINTENANCE INSTRUCTIONS ANNUAL INSPECTION or soot deposits then there may be a problem with the heater or the gas supply. The unit should be inspected at least once per year by a qualified service technician A heater should not be used if you suspect including inspection of the flue system.
  • Page 17 • ELECTRIC MOTOR MAINTENANCE Motors are permanently lubricated and need no lubrication. Keep fan and motor free of dust and dirt, clean annually. The heater should be serviced annually only by an authorised person. • GLASS REPLACEMENT AND CLEANING. (May be performed by the owner) It is best to handle the glass with clean NOTE:...
  • Page 18: Wiring Diagram

    WIRING DIAGRAM Wiring Diagram Wiring Diagram Ladder Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. TROUBLE SHOOTING SYMPTOM CAUSE SOLUTION Burner will not light No power present Ensure power cord is plugged in and turned on No gas present...
  • Page 19: Exploded Diagrams

    EXPLODED DIAGRAMS...
  • Page 21: Parts List

    PARTS LIST ITEM NO. QTY. PART NO. DESCRIPTION FLUE SPIGOT ASSY NAT IB USA 7993-1 HEAT EXCHANGER FRONT ASSY 3+3H 7074 HEAT EXCHANGER REAR ASSY 3H 7075 BURNER EXCHANGER TRANSFER TUBE 6624 BURNER HEAT EXCHANGER BRACKET 6625 COMB CHAMB ASSY IBR US PAINTED 7997 FRONT PANEL PAINTED VIPER IBR 7195V...
  • Page 22: Installation Notes

    REAR PANEL IBR USA 7989 REAR TOP PANEL IBR 7197 REAR SIDE PANEL LH IBR 7198 SURR TOP PANEL IBR VIPER 7190V SURROUND LEFT HAND IBR VIPER 7191V SURROUND RIGHT HAND IBR VIPER 7192V DOOR SPRING IBR 7177 DOOR LH IBR VIPER 7193V DOOR RH IBR VIPER 7194V...
  • Page 23: Installation / Commissioning Checklist

    INSTALLATION / COMMISSIONING CHECKLIST 1. Was a fireplace inspection carried out? (i.e. clearances, combustibles etc.) 2. Was a manufactured flue system installed? 3. Has specified gas pressure been set? 4. Are decorative logs located correctly on pins? 5. Have ember granules been placed and free of dust and powder? 6.
  • Page 24 Part Number 7918...

This manual is also suitable for:

Ib35rblIb35rbusIb35rus