Pressure Setting - SMC Networks ZSE20B-L Operation Manual

Digital pressure switch
Table of Contents

Advertisement

Pressure Setting

Default settings
When the pressure exceeds the set value, the switch will be turned on. When the pressure falls below the set
value by the amount of hysteresis or more, the switch will be turned off. The default setting is to turn on the
pressure switch when the pressure reaches the center of the atmospheric pressure and upper limit of the
rated pressure range. If this condition, shown to the below, is acceptable, then keep these settings.
●ISE20B
Item
[P_1] Set value of OUT1
[H_1] Hysteresis of OUT1
●ZSE20B
Item
[P_1] Set value of OUT1
[H_1] Hysteresis of OUT1
●ZSE20BF
Item
[P_1] Set value of OUT1
[H_1] Hysteresis of OUT1
Zero-clear of display
The display is reset to zero when the
For the first operation, perform a zero-clear without pressure at measurement mode.
Default setting
0.500 MPa
[P_2] Set value of OUT2
0.050 MPa
[H_2] Hysteresis of OUT2
Default setting
-50.0 kPa
[P_2] Set value of OUT2
5.0 kPa
[H_2] Hysteresis of OUT2
Default setting
50.0 kPa
[P_2] Set value of OUT2
5.0 kPa
[H_2] Hysteresis of OUT2
and
buttons are pressed simultaneously for 1 second.
-23-
Item
Default setting
0.500 MPa
0.050 MPa
Item
Default setting
-50.0 kPa
5.0 kPa
Item
Default setting
50.0 kPa
5.0 kPa
No.PS※※-OMV0006-D